WARNING
Solvent gases and vapors from dry cleaning machines create acids when drawn through the heater of a drying tumbler. These acids are corrosive to the drying tumbler as well as to the laundry load being dried. Be sure
If the dry cleaning machines are in the same area as the tumbler, then the tumbler
asource free of solvent gases and vapors.
WARNING
To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building.
FOR BEST PERFORMANCE Provide an individual exhaust duct for each tumbler. Do not install a hot water heater in room containing tumblers. It is better to have the water heater in a separate room with a separate air inlet.
NOTE: Do not install wire mesh or screen in this opening as lint will build up and prevent proper discharge of air from tumblers.
ROOF 30" (76.2 CM)
T075IE3A
ROOF 30" (76.2 cm)
CEILING
REMOVABLE STRIP OF PANEL IN FRAMING WALL TO
PERMIT REMOVAL OF TUMBLER FROM FRAMING WALL
PARTITION OR
BULKHEAD
WALL
36INCHES (91.4 cm)
RECOMMENDED SERVICE AREA
24INCHES (61.0 cm)
MINIMUM
ONE
TUMBLER
T108IE3A | TWO |
| TUMBLERS |
THREE
TUMBLERS
T108IE3B
CONSULT YOUR LOCAL BUILDING CODE FOR REGULATIONS WHICH MAY ALSO APPLY
NOTE: Inside of duct shall be smooth. Do not use sheet metal screws to join sections.
Figure 1