ELECTRICAL REQUIREMENTS
For 30 Pound (13 kg) Tumblers
REQUIREMENTS
Heat Source | Electrical Specs | Wires Required and Terminal Block Connection | |||
|
|
|
|
|
|
Gas & Steam | 230/50/1 | L1 | L2 |
| Ground to PE Busbar |
|
|
|
|
|
|
Electric | 230/50/1 | L1 | L2 |
| Ground to PE Busbar |
|
|
|
|
|
|
Electric | 380/50/3 | L1 | L2 | L3 | Ground to PE Busbar |
|
|
|
|
|
|
Electric | 415/50/3 | L1 | L2 | L3 | Ground to PE Busbar |
|
|
|
|
|
|
Steam | 380/50/3 | L1 | L2 | L3 | Ground to PE Busbar |
|
|
|
|
|
|
Figure 7
GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS
GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS
| 240 V, 1 Phase, 50 Hz. | 380 V, 3 Phase, 50 Hz. |
|
|
|
Minimum Wire Size | 14 AWG (2.081 mm²) | 14 AWG (2.081 mm²) |
|
|
|
Circuit Breaker | 15 AMP | 15 AMP |
|
|
|
Poles | 2 | 2 |
|
|
|
Figure 8
ELECTRIC DRYING TUMBLERS
NOTE: DO NOT use aluminum wire.
ELECTRIC DRYING TUMBLERS
| 240 V, 1 Ph, 50 Hz. | 240 V, 3 Ph, 50 Hz. | 380 V, 3 Ph, 50 Hz. | 415 V, 3 Ph, 50 Hz. |
|
|
|
|
|
Minimum Wire Size | 2 AWG (33.63 mm²) | 6 AWG (13.32 mm²) | 8 AWG (8.366 mm²) | 8 AWG (8.366 mm²) |
|
|
|
|
|
AMP Rating | 90 Amp | 54 Amp | 33 Amp | 30 Amp |
|
|
|
|
|
Circuit Breaker | 100 Amp | 60 Amp | 40 Amp | 35 Amp |
|
|
|
|
|
Poles | 2 | 3 | 3 | 3 |
|
|
|
|
|
Figure 9
36 | M412616 |