ELECTRICAL REQUIREMENTS

For 30 Pound (13 kg) Tumblers

REQUIREMENTS

Heat Source

Electrical Specs

Wires Required and Terminal Block Connection

 

 

 

 

 

 

Gas & Steam

230/50/1

L1

L2

 

Ground to PE Busbar

 

 

 

 

 

 

Electric

230/50/1

L1

L2

 

Ground to PE Busbar

 

 

 

 

 

 

Electric

380/50/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Electric

415/50/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Steam

380/50/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Figure 7

GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS

GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS

 

240 V, 1 Phase, 50 Hz.

380 V, 3 Phase, 50 Hz.

 

 

 

Minimum Wire Size

14 AWG (2.081 mm²)

14 AWG (2.081 mm²)

 

 

 

Circuit Breaker

15 AMP

15 AMP

 

 

 

Poles

2

2

 

 

 

Figure 8

ELECTRIC DRYING TUMBLERS

NOTE: DO NOT use aluminum wire.

ELECTRIC DRYING TUMBLERS

 

240 V, 1 Ph, 50 Hz.

240 V, 3 Ph, 50 Hz.

380 V, 3 Ph, 50 Hz.

415 V, 3 Ph, 50 Hz.

 

 

 

 

 

Minimum Wire Size

2 AWG (33.63 mm²)

6 AWG (13.32 mm²)

8 AWG (8.366 mm²)

8 AWG (8.366 mm²)

 

 

 

 

 

AMP Rating

90 Amp

54 Amp

33 Amp

30 Amp

 

 

 

 

 

Circuit Breaker

100 Amp

60 Amp

40 Amp

35 Amp

 

 

 

 

 

Poles

2

3

3

3

 

 

 

 

 

Figure 9

36

M412616