50 Pound (22 kg) Tumblers

LOW PRESSURE STEAM DRYING TUMBLERS

LOW PRESSURE STEAM DRYING TUMBLERS

 

 

240 V

 

 

1 Phase, 50 Hz.

 

 

 

Minimum Wire Size

 

14 AWG (2.081 mm²)

 

 

 

Circuit Breaker

 

15 AMP

 

 

 

Poles

 

2

 

 

 

 

Figure 14

GROUNDING INSTRUCTIONS

Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to the PE Busbar.

￿WARNING

To reduce the risk of fire and electric shock, check with a qualified service technician for proper grounding procedures. Improper connection of the equipment grounding conductor can result in a risk of electric shock.

￿WARNING

To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.

M412616