50 Pound (22 kg) Tumblers
LOW PRESSURE STEAM DRYING TUMBLERS
LOW PRESSURE STEAM DRYING TUMBLERS
|
| 240 V |
|
| 1 Phase, 50 Hz. |
|
|
|
Minimum Wire Size |
| 14 AWG (2.081 mm²) |
|
|
|
Circuit Breaker |
| 15 AMP |
|
|
|
Poles |
| 2 |
|
|
|
| Figure 14 |
GROUNDING INSTRUCTIONS
Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to the PE Busbar.
WARNING
To reduce the risk of fire and electric shock, check with a qualified service technician for proper grounding procedures. Improper connection of the equipment grounding conductor can result in a risk of electric shock.
WARNING
To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.
M412616 | 39 |