POSITIONING DRYING TUMBLER

Tumbler may be removed from skid before moving to installation location or moved while still attached to skid. Remove tumbler from skid by unscrewing four shipping capscrews (one at each corner) and remove tumbler from skid. Lint panel door will have to be removed in order to remove two front capscrews.

Screw four leveling legs back into level adjusting fittings from top. Slide tumbler to its permanent location and level. Keep tumbler as close to floor as possible. All four legs must rest firmly on floor so weight of tumbler is evenly distributed. Tumbler must not rock.

NOTE: Do not throw these four capscrews away

they are the leveling legs.

LEVELING DRYING TUMBLER

Each tumbler should be leveled within ¹⁄₈ inch

(3.2 mm) from front to rear, and ¹⁄₈ inch (3.2 mm) from side to side. Check front to rear level by rotating clothes cylinder until one rib is at bottom, then place a

level on bottom rib. Side to side level should be checked by placing a level on front and rear of top panel.

GAS REQUIREMENTS (Gas Drying Tumblers)

Size of gas service pipe is dependent upon many variables (lengths, tees, etc.). Specific pipe size information should be obtained from gas supplier. Refer to table in Figure 22 for general pipe size data.

It is important that equal gas pressure be maintained at all tumbler gas connections. This can best be done by installing a one inch pipe gas loop as shown in Figures 20 and 21.

￿WARNING

To reduce the risk of fire or explosion, if the tumbler is to be connected to Liquefied Petroleum (L.P.) gas, a vent to the outdoors must be provided in the room where the tumbler is installed.

42

M412616