ELECTRICAL REQUIREMENTS
For 75 Pound (34 kg) Tumblers
REQUIREMENTS
Heat Source | Electrical Specs | Wires Required and Terminal Block Connection | |||
|
|
|
|
|
|
Gas & Steam | 230/50/1 | L1 | L2 |
| Ground to PE Busbar |
|
|
|
|
|
|
Electric | L1 | L2 | L3 | Ground to PE Busbar | |
|
|
|
|
|
|
Electric | 380/50/3 | L1 | L2 | L3 | Ground to PE Busbar |
|
|
|
|
|
|
Electric | 415/50/3 | L1 | L2 | L3 | Ground to PE Busbar |
|
|
|
|
|
|
Steam | 380/50/3 | L1 | L2 | L3 | Ground to PE Busbar |
|
|
|
|
|
|
Figure 15
GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS
GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS
| 208V / 240 V | 208 / 240 V | 380 / 415 V |
| 1 Phase, 50 Hz. | 3 Phase, 50 Hz. | 3 Phase, 50 Hz. |
|
|
|
|
Minimum Wire Size | 14 AWG (2.081 mm²) | 14 AWG (2.081 mm²) | 14 AWG (2.081 mm²) |
|
|
|
|
Circuit Breaker | 15 AMP | 15 AMP | 15 AMP |
|
|
|
|
Poles | 2 | 3 | 3 |
|
|
|
|
Figure 16
ELECTRIC DRYING TUMBLERS
NOTE: DO NOT use aluminum wire.
ELECTRIC DRYING TUMBLERS
| 380 V, 3 Ph, 50 Hz. | 415 V, 3 Ph, 50 Hz. |
|
|
|
Minimum Wire Size | 6 AWG (13.32 mm²) | 6 AWG (13.32 mm²) |
|
|
|
AMP Rating | 48 Amp | 45 Amp |
|
|
|
Circuit Breaker | 50 Amp | 50 Amp |
|
|
|
Poles | 3 | 3 |
|
|
|
Figure 17
GROUNDING INSTRUCTIONS
Drying tumbler must be grounded. In event of malfunction or breakdown. Grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to PE Busbar.
aWARNING
To reduce the risk of fire and electric shock, check with a qualified service technician for proper ground procedures. Improper connection of the equipment grounding conductor may result in risk of electric shock.
WARNING
To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.
40 | M412616 |