ELECTRICAL REQUIREMENTS

For 75 Pound (34 kg) Tumblers

REQUIREMENTS

Heat Source

Electrical Specs

Wires Required and Terminal Block Connection

 

 

 

 

 

 

Gas & Steam

230/50/1

L1

L2

 

Ground to PE Busbar

 

 

 

 

 

 

Electric

208-230/50-60/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Electric

380/50/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Electric

415/50/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Steam

380/50/3

L1

L2

L3

Ground to PE Busbar

 

 

 

 

 

 

Figure 15

GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS

GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS

 

208V / 240 V

208 / 240 V

380 / 415 V

 

1 Phase, 50 Hz.

3 Phase, 50 Hz.

3 Phase, 50 Hz.

 

 

 

 

Minimum Wire Size

14 AWG (2.081 mm²)

14 AWG (2.081 mm²)

14 AWG (2.081 mm²)

 

 

 

 

Circuit Breaker

15 AMP

15 AMP

15 AMP

 

 

 

 

Poles

2

3

3

 

 

 

 

Figure 16

ELECTRIC DRYING TUMBLERS

NOTE: DO NOT use aluminum wire.

ELECTRIC DRYING TUMBLERS

 

380 V, 3 Ph, 50 Hz.

415 V, 3 Ph, 50 Hz.

 

 

 

Minimum Wire Size

6 AWG (13.32 mm²)

6 AWG (13.32 mm²)

 

 

 

AMP Rating

48 Amp

45 Amp

 

 

 

Circuit Breaker

50 Amp

50 Amp

 

 

 

Poles

3

3

 

 

 

Figure 17

GROUNDING INSTRUCTIONS

Drying tumbler must be grounded. In event of malfunction or breakdown. Grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to PE Busbar.

aWARNING

To reduce the risk of fire and electric shock, check with a qualified service technician for proper ground procedures. Improper connection of the equipment grounding conductor may result in risk of electric shock.

￿WARNING

To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.