VERTICAL EXHAUST INSTALLATION | HORIZONTAL EXHAUST INSTALLATION |
WALL
CONNECT TO
TUMBLER
2" (5.1 cm)
MINIMUM
WALL
CONNECT TO | 2" (5.1 cm) |
TUMBLER | MINIMUM |
EXHAUST
EXHAUST AIR FLOWOUTLET MAXIMUM LENGTH OF
DUCT 14 FEET
(4.3 m)
NO SCREEN
OR CAP
T030IE3B
NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm)
LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING.
Figure 2
NOTE: WHERE THE EXHAUST DUCT PIERCES A COMBUSTIBLE WALL OR CEILING, AN OPENING HAVING A DIAMETER FOUR INCHES (10.2 cm)
LARGER THAN THE DIAMETER OF THE EXHAUST DUCT SHALL BE PROVIDED, AND THE EXHAUST DUCT CENTERED WITHIN THE OPENING.
INSPECTION OR
CLEANOUT COVER
WALL | L K J I H G F E D C B A |
|
2" (5.1 cm)
MINIMUM
|
|
|
|
|
| 45˚ | |
NO SCREEN |
|
|
|
|
| T056IE3B | |
OR CAP |
|
|
|
|
|
| |
| AIR OUT |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| DUCT | MINIMUM DIAMETER | DUCT | MINIMUM DIAMETER |
| ||
|
|
|
|
|
| ||
| *GAS |
| *GAS |
|
| ||
| STATION | STEAM | STATION | STEAM |
| ||
| ELECTRIC | ELECTRIC |
| ||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| A | 9" (22.9 cm) | 10" (25.4 cm) | G | 23" (58.4 cm) | 26" (66 cm) |
|
|
|
|
|
|
|
|
|
| B | 12" (30.5 cm) | 14" (35.6 cm) | H | 25" (63.5 cm) | 28" (71.1 cm) |
|
|
|
|
|
|
|
|
|
| C | 15" (38.1 cm) | 17" (43.2 cm) | I | 26" (66 cm) | 30" (76.2 cm) |
|
|
|
|
|
|
|
|
|
| D | 17" (43.2 cm) | 20" (50.8 cm) | J | 27" (68.6 cm) | 31" (78 cm) |
|
|
|
|
|
|
|
|
|
| E | 19" (48.3 cm) | 22" (55.9 cm) | K | 29" (73.9 cm) | 33" (83.8 cm) |
|
|
|
|
|
|
|
|
|
| F | 21" (53.3 cm) | 24" (61 cm) | L | 30" (76.2 cm) | 34" (86.4 cm) |
|
|
|
|
|
|
|
|
|
Figure 3
34 | M412616 |