Staber Industries HXW2304 Replace Pressure Switch, Replace Water Valve, Replace LID Lock Switch

Models: HXW2404 HXW2505 HXW2405 HXW2304 HXW2305 HXW2504

1 20
Download 20 pages 39.68 Kb
Page 12
Image 12

12

REPLACE PRESSURE SWITCH

1Disconnect the appliance from the power source.

2Remove the six philips head screws that hold the control panel to the top.

3Allow the control panel to slide down, pull the top of the control panel out and lift up.

4Lay the control panel face down on the top.

5Pull up on the pressure switch that is fastened to the bottom of the

control housing.

6 Remove the connectors from the switch.

7 To install a new switch, reverse the above procedures. 8 Plug power cord into electrical receptacle.

REPLACE WATER VALVE

1 Disconnect the appliance from the power source.

2Shut off the hot and cold water supply.

3Remove the six screws that hold the control panel to the top.

4Allow the control panel to slide down, pull the top of the control panel out and lift up.

5Lay the control panel face down on the top.

6Using a 5/16 nut driver, remove the water valve hold down nut located between the two electrical coils on the valve. Lift the water valve from the control panel.

7Note on a piece of paper, position and color of electrical wires on the water valve. Remove the wires from the valve.

8Remove the two inlet hoses from the water valve.

9Remove the outlet hose from the water valve.

10Install a the new water valve on the clothes washer by reversing the

above procedures.

11 Turn on both water supplies. Check for water leaks. 12 Plug the power cord into electrical receptacle.

REPLACE LID LOCK SWITCH

1Remove the front panel as directed under "REMOVE FRONT PANEL".

2Remove two screws from lid lock switch bracket and remove switch from clothes washer.

3Note on a piece of paper, position of wiring plug on switch. Remove plug from switch.

4Install plug on new switch as noted and install switch on clothes washer. Reinstall front cover as directed under "INSTALL FRONT PANEL" and plug power cord into electrical receptacle.