OPERATION
PRE-OPERTION PROCEDURES
CHECK THE POWER SOURCE
1.Using a calibrated flow meter and pressure gauge, make sure the hydraulic power source develops a flow of
2.Make certain that the power source is equipped with a relief valve set to open at
3.Check that the hydraulic circuit matches the tool for
CHECK TOOL
1.Make sure all tool accessories are correctly in- stalled. Failure to install tool accessories properly can result in damage to the tool or personal injury.
2.There should be no signs of leaks.
3.The tool should be clean, with all fittings and fasten- ers tight.
4.Observe the arrow on the couplers to ensure that the hydraulic oil flow is in the proper direction. The female coupler is the inlet (pressure) coupler.
5.Check that the trigger operates smoothly and is free to travel between the ON and OFF positions.
6.Check that the chain is properly installed. The chain is designed to only operate in one direction. Make sure the chain is installed so the bumper guard pre- cedes each diamond segment. See Figure 2.
| Segment |
CORRECT | Bumper |
Guard |
INCORRECT
Figure 2. Chain Direction
CONNECT HYDRAULIC HOSES
1.Wipe all hose couplers with a clean
2.Connect the hoses from the hydraulic power source to the chain saw fittings or quick disconnects. It is a good practice to connect return hose first and dis- connect them last to minimize or avoid trapped pres- sure within the chain saw.
3.Observe the arrow on the couplers to ensure that the flow is in the proper direction. The female cou- pler on the chain saw is the inlet (pressure) coupler.
NOTE:
If uncoupled hoses are left in the sun, pressure in- crease inside the hoses might make them difficult to connect. Whenever possible, connect the free ends of the hoses together.
CONNECTING TO A WATER SUPPLY
1.Using a standard garden hose, connect the DS06 to a city or auxiliary water supply. Make sure the flow is at least 4 gpm/15 lpm at 50 psi/3.5 bar.
IMPORTANT
Chain and bar damage will occur if the tool operates without the proper water supply and water pressure.
2.Make sure the water is running before starting the tool.
3.If a water pump is being used, refer to the manu- facturers instructions for use of the pump. Make sure the pump produces a minimum water flow of 4 gpm/15 lpm at 50 psi/3.5 bar and the water pressure does not exceed 160 psi/11 bar.
CHECK CHAIN AND BAR ADJUSTMENT
NOTE:
Check the chain tension often during operation, es- pecially during the first 1/2 hour when using a new chain. Adjust the chain accordingly when it becomes loose. Follow the procedures contained in the Main- tenance and Adjustments section of this manual.
1.Make sure the chain does not exceed a clearance of 5/16 in./8 mm from the bar (see Figure 3). Exceed-
DS06 User Manual ◄ 11