TROUBLESHOOTING
EP30200
PROBLEM | CAUSE | SOLUTION | |
Brazing pin does not ignite |
| Test batteries for proper charge. Replace and/or | |
or does not ignite long | Batteries not charged or are defective. | ||
charge as necessary. | |||
enough. |
|
| |
| Blown fuse. | Check fuses. | |
|
| Check that surface magnetic ground is applied to | |
| Magnetic ground faulty. | is ground clean. Check magnetic ground cable | |
|
| and plug for damage. | |
| Faulty cables. | Check gun cables and plugs for damage. | |
| Bonding surface contaminated. | Check that the brazing surface is ground clean. | |
Braze is faulty. | Batteries not charged or are defective. | Test batteries for proper charge. Replace and/or | |
charge as necessary. | |||
| Incorrect PIN TYPE setting. | Check PIN TYPE setting on the control box. | |
|
| Check that surface magnetic ground is applied to | |
| Magnetic ground faulty. | is ground clean. Check magnetic ground cable | |
|
| and plug for damage. | |
| Bonding surface contaminated. | Check that the brazing surface is ground clean. | |
| Incorrect grinding wheel is used. | Use only Tyrolit grinding wheels or carbide burr. | |
| Ceramic ring was not positioned | Ensure ring is positioned correctly. | |
| square to the lug. | ||
|
| ||
| Brazing pin not positioned correctly in | Ensure pin is positioned correctly. | |
| lug hole. | ||
|
|