SECTION Vl - TROUBLE SHOOTING
| Trouble | Probable Cause |
| Remedy |
| |
Hoist Will Not Operate. | a. No power to hoist. |
| a. Check switches, circuit breakers or fuses and |
| ||
|
|
|
|
| connections in power supply lines. Check power |
|
|
|
|
|
| collectors. |
|
|
| b. Wrong voltage. |
| b. Check voltage required on motor data plate |
| |
|
|
|
|
| against power supply. |
|
|
| c. Loose or | broken | wire | c. Shut off power supply, remove electrical cover on |
|
|
| connections | in hoist electrical | hoist and check wiring connections. Also check |
| |
|
| system. |
|
| connections in push button station and limit |
|
|
|
|
|
| switches. |
|
|
| d. Contactor | assembly | not | d. See that necessary jumper wires are properly |
|
|
| functioning. |
|
| installed. Verify that the contactor armatures are |
|
|
|
|
|
| free to move. If binding occurs, replace contactor. |
|
|
|
|
|
| Check for burned out contactor coils. |
|
|
| e. No control voltage. |
| e. Check transformer fuse. If blown, check for |
| |
|
|
|
|
| grounding and/or shorts in the push button station. |
|
|
|
|
|
| Check the transformer coil for signs of |
|
|
|
|
|
| overheating. Replace transformer if burned out. |
|
|
|
|
|
| Verify the transformer secondary is the same |
|
|
|
|
|
| voltage as the coils to which it is connected. |
|
|
| f. Motor burned out. |
| f. Replace motor. Check input power supply. Check |
| |
|
|
|
|
| hoist motor connections. |
|
|
|
|
|
| ||
Hook Moves in Wrong | a. Reverse phasing on three- | a. Interchange any two power supply line leads. |
| |||
| Direction. | phase hoists. |
| Refer to Section II, paragraph |
| |
|
| b. Hoist wired wrong. |
| b. Check wiring connections with appropriate wiring |
| |
|
|
|
|
| diagram. |
|
|
|
|
|
| ||
Hook Will Raise But | a. Lower electrical circuit open. | a. Check for loose connections. See that necessary |
| |||
Not Lower. |
|
|
| jumper wires are properly installed on contactor. |
| |
|
| b. Contactor | assembly | not | b. See that necessary jumper wires are properly |
|
|
| functioning. |
|
| installed. Verify that the contactor armatures are |
|
|
|
|
|
| free to move. If binding occurs, replace contactor. |
|
|
|
|
|
| Check for burned out contactor coils. |
|
|
| c. Down, push button inoperative. c. Check push button contacts and wires. |
|
a. Excessive load. | a. Reduce loading to rated load of hoist, as shown | |
Not Raise. |
| on nameplate. |
| b. Hoist electrical circuit open. | b. Check for loose connections. See that necessary |
|
| jumper wires are properly installed on contactor. |
|
| Check limit switch mounting and connections. |
| c. Contactor assembly not | c. See that necessary jumper wires are properly |
| functioning. | installed. Verify that the contactor armatures are |
|
| free to move. If binding occurs, replace contactor. |
|
| Check for burned out contactor coils. |
d. Up, push button inoperative.
d. Check push button contacts and wires.
Page 19