AA-9 Troubleshooting

Cannot connect to GA-1120 with Fiery utilities

If users cannot connect to the GA-1120, check the following:

GA-1120 Setup—the appropriate network protocol must be enabled, with the correct parameters (for example, for TCP/IP, the IP address), and you must publish either the Print queue or Hold queue.

You can check these settings quickly by printing a Configuration page.

On the client workstation—the appropriate network protocol(s) must be loaded, and your Windows directory should contain a configured Efinl.ini file.

Cannot connect to the GA-1120 with Command WorkStation

If there is a problem connecting to the GA-1120, an error message is displayed.

The problem can occur when:

The GA-1120 is first turned on

The GA-1120 restarts

You have changed settings affecting the server address and have not reconfigured the connection to the server

If you see this problem, try the following solutions, in this order:

A remote workstation running Fiery utilities or WebTools may be interfering by obtaining status information. If possible, close the remote application, and try to connect again.

Restart the Command WorkStation software and try to connect again.

Check the configuration of the connection and modify it, if necessary, or delete the Efinl.ini file and start over with the process of configuring the connection as described in the User Software Installation Guide.

For Windows9x/Me, the Efinl.ini file is located in \WINDOWS.

For Windows NT 4.0/2000/XP, the Efinl.ini file is located in \WINNT.

Restart the GA-1120.

For information on other error conditions, see the Job Management Guide.