OPERATION

OPERATING PROCEDURES

COLD WEATHER OPERATION

Observe all safety precautions given in this manual. If the RV06 is to be used during cold weather, preheat

• Refer to the applicable manual for the tool connect-

the hydraulic fluid at low engine speed. When using the

normally recommended fluids, fluid temperature should

ed to the RV06.

be at or above 50 °F/10 °C (400 ssu/82 centistokes) be-

• Activate the parent circuit to provide power to the in-

fore use.

tensifier. Pressure will now be available at the pres-

Damage to the hydraulic system or RV06 can result

sure port of the RV06.

from use with fluid that is too viscous or thick.

• To advance the ram of the connected tool, press the

 

forward end of the rocker arm.

 

• When the crimp or cut is complete, release the rock-

 

er arm and the RV06 will go to a “neutral” or “hold”

 

position. The tool ram will remain stationary.

 

• To retract the tool ram, press the rear of the rocker

 

arm. If the RV06 is connected to a double-acting

 

tool, the ram will retract under power. If the tool is

 

single-acting, the ram will retract somewhat more

 

slowly due to its spring return.

 

RV06 User Manual ◄ 11