Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
CHAPTER 4: DAILY OPERATION
4.2Start-Up Procedures (cont.)
B.Pilot lighting procedure – Electronic Ignition
a.Turn gas "ON."
b.Turn electric power "ON" with the appropriate rocker switch or controller/controller.
c.The ignition module will energize the pilot gas supply and the ignitor. The ignitor spark will ignite the pilot gas. The presence of the pilot flame is then proven by a flame sensor, which sends a signal to the main gas supply, opening the valve. The operating thermostat or controller/controller controls the fryer after ignition.
WARNING
In the event of prolonged power failure, the ignition module will shut down and lock out the system. Turn the unit power "OFF" and then back "ON" after power has been
d.If the pilot flame fails, the ignition module will shut down and lock out the system. To restart, turn the electric power "OFF,” wait approximately 5 minutes for the system to recycle itself, and then turn the power "ON" again. Repeat Steps
3.
ON/OFF Buttons
NOTE: For