Manuals
/
Brands
/
Kitchen Appliance
/
Fryer
/
Frymaster
/
Kitchen Appliance
/
Fryer
Frymaster
Y/KSCF/C/HC18G operation manual
Please, tick the box below to download manual:
Contents
Main
*8196329*
Y/KSCF/C/HC18G High Efficiency
Installation and Operation Manual
Cool Zone Series Gas Fryers
Please read all sections of this manual and retain for future reference.
Page
Y/KSCF/C/HC18G Cool Zone Gas Fryers
TABLE OF CONTENTS
Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 1: INTRODUCTION
1.3 Service Information
1.4 Controller Information
1.5 Safety Information
1.5 Safety Information (cont.)
1.6 Service Personnel
Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION
2.1 Receiving and Unpacking Equipment
2.2 General
2.3 Principles of Operation
2.4 Rating Plate
2.5 Pre-Installation
2.5 Pre-Installation (cont.)
2.6 Air Supply and Ventilation
2.7 Equipment Installed at High Altitudes
2.8 Restraining the Fryer
Page
Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS
3.1 Installing the Fryer
3.2 Leg and Caster Installation
3.2 Leg and Caster Installation (cont.)
3.3 Leveling the Fryer
3.3 Leveling the Fryer (cont.)
3.3 Leveling the Fryer (cont.)
3.4 Gas Connections
Page
Page
3.4 Gas Connections (cont.)
3.5 Adjustments/Adaptation To Different Gases
3.6 Gas Conversion: Procedures
3.7 Electrical Connections
3.8 Safety Switches
Page
3.8 Safety Switches (cont.)
3.9 Initial Cleaning Before Startup
3.10 Final Preparation
3.10 Final Preparation (cont.)
For pilot lighting instructions, see Chapter 4. For filtration instructions, see Chapter 5.
Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION
4.1 General Use
4.2 Start-Up Procedures
4.2 Start-Up Procedures (cont.)
4.3 Filtering
4.4 Closing
Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION
5.1 General
5.2 Filter Preparation
5.2 Filter Preparation (cont.)
Page
5.3 Filter Operations
Page
Page
5.3 Filter Operations (cont.)
5.3 Filter Operations (cont.)
Page
6.1 Daily
6.2 Weekly
6.3 Periodic/Annual
6.3 Periodic/ Annual (cont.)
6.4 Stainless Steel
Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING
7.1 Introduction
Before calling a service agent or the Frymaster Dean HOTLINE (1-800-551- 8633):
7.2 Fryer Troubleshooting
7.2.1
gas valves fail to energize.
Controller fails to turn ON when ON/OFF button is pressed.
7.2.3
differs from the controller setpoint temperature.
7.2.3 (cont.)
Actual frypot temperature differs from controller setpoint temperature.
Burner Tube
7.2 Fryer Troubleshooting (cont.)
7.2.4
stops during filtering.
remains after closing drain valve.
7.2.5
Fryer Troubleshooting (cont.)
7.2.6
Y/KSCF/C/HC18G HIGH EF FICIEN CY COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING
7-7
7.3 Filtration System Troubleshooting