Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
CHAPTER 7: TROUBLESHOOTING
Fryer Troubleshooting (cont.)
7.2.6
Main burner malfunctions.
A.Main burner will not ignite; no gas is present at main burner.
1.Check that float switch is not stuck in the "down" position.
2.Check and reset the
3.The combination gas valve and/or electronic ignition system may be defective; Contact a FAS for service.
B.Main burner flames are small and appear lazy; shortening does not come up to temperature quickly. Contact a FAS for service.
C.Fryer will not reach setpoint temperature and/or runs erratically.
1.Incorrect location or adjustment of sensor probe. Contact a FAS for service.
2.Defective temperature sensor. Contact a FAS for service.
D.Fryer shortening temperature cannot be controlled; fryer runs at
1.Defective operating thermostat. Contact a FAS for service.
2.Defective temperature probe. Contact a FAS for service.