Frymaster Y/KSCF/C/HC18G Fryer Troubleshooting cont, 7.2.6, Main burner malfunctions

Models: Y/KSCF/C/HC18G

1 54
Download 54 pages 45.96 Kb
Page 47
Image 47
Fryer Troubleshooting (cont.)

Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

Fryer Troubleshooting (cont.)

7.2.6

Main burner malfunctions.

A.Main burner will not ignite; no gas is present at main burner.

1.Check that float switch is not stuck in the "down" position.

2.Check and reset the high-limit switch.

3.The combination gas valve and/or electronic ignition system may be defective; Contact a FAS for service.

B.Main burner flames are small and appear lazy; shortening does not come up to temperature quickly. Contact a FAS for service.

C.Fryer will not reach setpoint temperature and/or runs erratically.

1.Incorrect location or adjustment of sensor probe. Contact a FAS for service.

2.Defective temperature sensor. Contact a FAS for service.

D.Fryer shortening temperature cannot be controlled; fryer runs at high-limit temperature. Possible causes are:

1.Defective operating thermostat. Contact a FAS for service.

2.Defective temperature probe. Contact a FAS for service.

7-6