Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
3.4Gas Connections (cont.)
2.For an appliance equipped with casters, the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, or Connectors for Moveable Gas Appliances,
3.The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Clips are located on the back panel of the fryer for the attachment of restraints.
4.If it is necessary to disconnect the restraint, it must be reconnected after the fryer has been returned to its originally installed position.
WARNING
Do not attach accessories to this fryer unless fryer is secured from tipping.
Personal injury may result.
F.After
WARNING
Qualified personnel MUST perform any adaptation, modification, or gas conversion,
if required. Failure to use qualified personnel will void the Frymaster warranty.
3.5Adjustments/Adaptation To Different Gases
A.Proper operation of appliances requires the operator to scrupulously inspect the following:
1.Gas inputs and pressures;
2.Voltage and polarities of electrical power supplies.
B.Frymaster gas fryers are manufactured to use the type of gas and pressure specified on the rating plate. When changing gas, adaptation must be performed by qualified personnel. Failure to use qualified personnel will void the Frymaster warranty.
Nominal "Qn" Heat Input for the Y/KSCF/C/HC18G High Efficiency Cool Zone Gas fryer is 25 kW.