Frypot Front

Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7.2 Fryer Troubleshooting (cont.)

Frypot Front

TemperatureHigh-Limit

ProbeProbe

Temperature Probe

Probe Bracket

Burner Tube

No: Ensure the probe tip is ⅛" from the top of the burner tubes (see illustration). If the probe adjustment is correct, the controller probe circuit may be faulty. If probe adjustment is incorrect, it will require adjustment.

6.Contact your authorized service agent if any of the following occurs during this test:

a.Controller probe circuit is suspected as faulty.

b.Temperature probe needs adjustment.

c.KFC-1 SMS controller fails to call for heat during the calibration test.

7-4