MOTOR WILL NOT RUN

1.Confirm 120V AC to the controller. Also, to verify correct polarity, check for 120 V AC between hot supply and ground.

If there is no voltage, check for a loose connection where it connects to the controller.

2.If there is 120 volts to the controller, check for loose connections or a locked rotor. If the rotor cannot be freed the motor and blower assembly must be replaced.

MOTOR RUNS, PREPURGE TIME ELAPSES BUT MAIN

FLAME NOT ESTABLISHED.

1.Check to see if main manual gas valve is open.

2.Check for a loose connection at the transformer, or a defective transformer.

3.Check for a loose connection at the gas valve.

4.Check for open pressure switches or open reset button. Check for blockage in the intake and exhaust venting or at the vent hoods. If no blockage is found, check vinyl tubing for cuts or crimps. If this tubing is damaged it must be replaced. If these steps do not eliminate the problem, replace the pressure switches.

5.Check to see if there is resistance across the igniter terminal with an OHM meter. If there is no continuity, the igniter is broken and should be replaced.

If the igniter appears to function properly, then verify that the inlet pressure is within the range shown in Table 4. The gas valve supplied on the appliance is not designed to open against a higher inlet pressure of 10.5"WC (2.59kPa) for natural gas and 14.0"WC (3.45kPa) for propane gas. At this time, also check to make sure the inlet pressure is not lower than 4.0"WC (.98kPa) for natural gas and 11.0"WC (2.74kPa) for propane gas. If the inlet pressure is not within these limits then adjust the supply pressure accordingly.

If the inlet pressure falls within the allowable limits, then verify that the manifold pressure, when the gas is fully open, with the heater running, is as called out in Table 4: that is, 4.0"WC (.98kPa) for natural gas and 10.0"WC (2.46kPa) for propane gas for the 120 and 150 models and 0"WC (0kPa) for both natural and propane gas 199 and 250 models. If the manifold pressure is not correct then adjust accordingly. See "ADJUSTMENT PROCEDURE" in "OPERATING INSTRUCTIONS" sections for manifold pressure adjustment procedure.

6.If the inlet and manifold pressures are within the limits specified in step 5, then reset the appliance. Verify 24V AC at the gas valve during the three

(3) second ignition trial, after the igniter reaches operating temperature. If 24V AC at the gas valve is not seen during this period, the controller must be replaced.

If there is 24V AC at the gas valve during the four second ignition trial and the manifold pressure does not increase above 0" W.C. then verify that the manual gas control valve is in the “ON” position (see page 20). If the valve is in the “ON” position and the previous voltage and gas pressure conditions are met, then the gas valve is defective and must be replaced.

Note that a positive manifold pressure reading of approximately 1.5" (.38 kPa) W.C. is normal during the prepurge portion of the ignition cycle due to the location of the gas orifice.

MOTOR RUNS, BURNER LIGHTS MOMENTARILY,

THEN LOCKS OUT

1.Reset the appliance two more times to ensure that all of the air has been purged from the gas line.

2.If the burner lights momentarily but does not sustain ignition, verify that the inlet pressure is not greater than 10.5" WC (2.59 kPa) for natural gas and 14.0" WC (3.45 kPa) for propane gas or lower than the minimal supply pressure which is 4.0" WC (.09kPa) for natural gas and 11.0"WC (2.74 kPa) for propane gas. Also, verify that the manifold pressure is correct, that is, 4.0"WC (.98kPa) for natural gas and 10.0"WC (2.46kPa) for propane gas for the 120 and 150 models and 0"WC (0kPa) for both natural and propane gas 199 and 250 models. If the manifold pressure is not correct then adjust accordingly. See "ADJUSTMENT PROCEDURE" in "OPERATING INSTRUCTIONS" sections for manifold pressure adjustment procedure.

3.Check for the reversed polarity in the supply wiring. This controller is polarity sensitive. If the hot and neutral supply wires are reversed, the controller will not sense flame. Reverse the supply wires and try to fire the unit.

NOTE: Always turn off and disconnect main supply wiring before servicing the unit.

4.Check connecting wire to the flame sensor. Verify that the flame sensor has not been damaged in any way.

5.Verify that the air supply is adequate. The air inlet screen or blower wheel may be restricted. Also, check the installation for proper ventilation. See

AIR REQUIREMENTS.

6.Check the venting system for the correct sizing, excess or insufficient.

See VENTING.

7.Check for maximum inlet pressure of 10.5"WC (2.59 kPa) for natural gas and 14.0"WC (3.45 kPa) for propane gas and the manifold pressure which is 4.0"WC (.98 kPa) for natural gas and 10.0"WC (2.46 kPa) for propane gas for the 120 and 150 models and 0"WC (o kPa) for both natural and propane gas 199 and 250 models. Please note that the manifold pressure listed is the maximum value for the manifold pressure. Do not set the manifold pressure higher than the value show in Table 4. OVER FIRING the heater will result in a rough ignition and/or noisy operation.

8.Confirm that the air inlet screen (see Figures 7 & 8) is free of obstructions.

CAUTION

Do not reach into the burner housing or combustion chamber if the heater is still hot. Allow the heater to cool and always use gloves as the combustion chamber and the burner sleeve and housing can become very hot after operation. OVER FIRING is a dangerous condition that must be corrected immediately.

GAS FAILS TO SHUT OFF

Check for defective gas valve or thermostat. If operation is incorrect, replace.

REPLACEMENT PARTS

Replacement parts may be ordered through State dealers, authorized servicers or distributors. Refer to the Yellow Pages for where to call or contact the State Water Heaters, 500 Tennessee Waltz Parkway, Ashland City, TN 37015, 1-800-821-2017. When ordering parts be sure to state the quantity, part number and description of the items including the complete model and serial number as it appears on the product. Refer to the parts list for more information.

35

Page 35
Image 35
State Industries 100, 101 Motor will not RUN, Motor RUNS, Burner Lights Momentarily Then Locks OUT, GAS Fails to Shut OFF

100, 101 specifications

State Industries 101,100 is an innovative company that specializes in manufacturing high-quality industrial equipment and machinery. Founded with a vision to enhance productivity and efficiency across various sectors, State Industries has established itself as a trusted name in the industry. The company is known for its commitment to quality, sustainability, and cutting-edge technology, making it a preferred choice for businesses looking to elevate their operations.

One of the main features of State Industries 101,100 is its extensive product line, which includes a wide range of industrial machines, tools, and systems. The company’s offerings are designed to cater to various industries, such as manufacturing, construction, energy, and transportation. From heavy-duty machinery to precision tools, State Industries ensures that its products meet the highest standards of performance and reliability.

A key aspect of State Industries’ success is its incorporation of advanced technologies in its manufacturing processes. The company utilizes state-of-the-art machinery and techniques, including computer-aided design (CAD), robotics, and automation. These technologies enable State Industries to produce parts and equipment with exceptional precision, which ultimately leads to improved overall performance. Additionally, the company places a strong emphasis on research and development, constantly seeking new ways to innovate and enhance its product offerings.

Sustainability is another defining characteristic of State Industries 101,100. The company is deeply committed to minimizing its environmental impact by adopting eco-friendly practices throughout its operations. This includes using sustainable materials, reducing waste during production, and implementing energy-efficient technologies. State Industries also actively engages in initiatives aimed at promoting green technology, striving to contribute positively to the environment while delivering high-quality industrial solutions.

Customer satisfaction remains a top priority for State Industries. The company fosters strong relationships with its clients by offering tailored solutions, responsive customer service, and comprehensive support throughout the product lifecycle. With a focus on understanding customer needs and challenges, State Industries is dedicated to delivering exceptional value and reliability with every product.

In summary, State Industries 101,100 stands out as a forward-thinking company that combines advanced technology, a commitment to sustainability, and a customer-centric approach in its operations. As industries evolve and face new challenges, State Industries is well-positioned to continue leading the way in industrial innovation.