Models: GS6 50 YOCT Series 200 GS6 30 YBRS Series 200 186489-002 GS6 50 YOCT Series 201 GS6 40 YBRS Series 200 GS6 40 YBRS Series 201 GS6 50 YBRS Series 200 GS6 30 YOCT Series 201 GS6 30 YBRT Series 200 GS6 30 YBRT Series 201 GS6 50 YBRT Series 201 GS6 30 YBRS Series 201 GS6 40 YOCT Series 200 GS6 40 YBRT Series 200 GS6 30 YOCT Series 200 GS6 50 YBRS Series 201 GS6 40 YBRT Series 201 GS6 50 YBRT Series 200 GS6 40 YOCT Series 201

1 36
Download 36 pages 6.3 Kb
Page 21
Image 21

Robertshaw Gas Control Valve/Thermostat - Lighting Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which is lighted by a piezoelectric igniter. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

ϖDo not try to light any appliance.

ϖDo not touch any electrical switch; do not use any phone in your building.

ϖImmediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

ϖIf you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or move by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to flood conditions or anytime the gas controls, main burner or pilot have been submerged in water require replacement of the entire water heater.

E.DO NOT USE THIS APPLIANCE IF THERE HAS BEEN AN IGNITION OF VAPORS. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to a flammable vapors ignition will show a discoloration on the air intake grid and require replacement of the entire water heater.

LIGHTING INSTRUCTIONS

1.STOP! It is imperative that you read all the safety warnings before lighting the pilot.

2.Remove the outer door.

3.Turn the temperature dial counterclockwise to its lowest setting.

 

 

RESET

130° F

 

 

 

120° F

 

 

BUTTON

BAR

 

 

 

BAR

 

 

 

 

 

 

 

 

GAS

 

 

 

 

 

 

 

 

CONTROL

 

 

WAR

 

 

 

 

KNOB

 

 

 

 

 

 

DIAL

AUTIO

 

M

 

 

 

 

 

 

 

READUNITROL

C

N

 

 

 

STOP

T

 

 

 

 

 

 

O

 

 

 

 

 

 

H

 

 

 

 

 

ALL

 

 

 

 

 

 

 

BEFOREWARNING

INDEX

 

 

 

 

 

 

 

INSTRUCTIONS

 

 

 

 

 

 

 

LIGHTING

BARS

T W

HO TTER

S

R Y

 

V

 

 

H A

 

 

WA

 

E TE

ASE

 

A

 

 

R

R INCRE

JU

 

C

 

R

 

IS

 

IN

 

 

7.Depress the reset button all the way in and IMMEDIATELY depress the igniter button until you hear a loud click. Observe the pilot through the view port. Do not release the reset button. Repeat immediately if pilot does not light on the first try. If the pilot does not light by the fourth attempt with the igniter, repeat steps 4 - 7. Continue to hold the button for about (1) minute after the pilot is lit. Release the reset button and it will pop back up. Pilot should remain lit. If the pilot light goes out, repeat steps 3 - 7.

PUSHBUTTON

IGNITER

C

M

K OF SCALD

 

A

 

AUTIO

 

 

N

130° F

T

 

 

OI

 

 

 

N

 

 

V

BAR

 

 

 

ACA

 

 

 

IT

 

 

 

4. Depress the dial stop and turn

O

N

O

CAUTION

gas control knob clockwise

 

DAMAGE

 

IP

 

 

ON DIAL

 

L

 

 

 

to the “OFF” position.

T

OFF

WILL

 

RESULT

5.To clear any gas that may have accumulated wait ten (10) minutes.

If you then smell gas, STOP! Follow “B” in the safety warning above. If you do not smell gas go to the next step.

 

 

 

CAUTION

 

 

 

DO NOT PRY

 

O

F

ON DIAL

6. Turn the gas control knob

F

DAMAGE

N

PILOT

 

 

 

O

WILL

 

 

 

RESULT

counterclockwise

 

 

 

to “PILOT”.

 

 

 

IMPORTANT: If the pilot will not stay lit after several tries, depress the dial stop and turn gas control knob to “OFF”, then call your service technician or gas supplier.

IMPORTANT: If the reset button (see graphic at step 3) does not pop up when released, stop and immediately shut off the gas at the line valve or tank. Call your service technician or gas supplier.

8.Turn the gas control knob counterclockwise

to “ON”.

T

ON DIAL

 

FFO

CAUTION

 

DO NOT PRY

 

O

DAMAGE

 

L

9. Set the temperature dial to

I

WILL

O N

 

 

P

RESULT

the desired setting.

 

 

10. Replace the outer door.

TO TURN OFF GAS TO APPLIANCE

1. Turn the temperature dial counterclockwise

to its

2. Turn the gas control knob clockwise

to the “OFF”

lowest setting.

 

position.

 

Checking the Draft

WARNING

Burn Hazard

Do not touch vent.

Doing so can result in burns.

DRAFT HOOD

RELIEF

OPENING

MATCH

After successfully lighting the water heater, allow the unit to operate for 15 minutes and check the draft hood relief opening for proper draft (Figure 17). Make sure all other appliances in the area are operating and all doors are closed when performing the draft test. Pass a match flame around the relief opening of the draft hood. A steady flame drawn into the opening indicates proper draft.

FIGURE 17.

If the flame flutters or is blown out, combustion products are escaping from the relief opening. If this occurs, do not operate the water heater until proper adjustments or repairs are made to the vent pipe system and/or air supply requirements.

21

Page 21
Image 21
State Industries GS6 50 YOCT Series 201, 186489-002, GS6 50 YOCT Series 200 Checking the Draft, Burn Hazard

GS6 50 YOCT Series 200, GS6 30 YBRS Series 200, 186489-002, GS6 50 YOCT Series 201, GS6 40 YBRS Series 200 specifications

State Industries has a long-standing reputation for manufacturing high-quality heating equipment, and their GS6 series continues this tradition with advanced technology and robust features. The GS6 40 YOCT Series 201, GS6 50 YBRT Series 200, GS6 40 YBRT Series 201, GS6 50 YBRS Series 201, and GS6 30 YOCT Series 200 are notable additions to their product lineup, each designed to meet varying heating demands and efficiency standards.

The GS6 40 YOCT Series 201 is engineered for residential applications where space and efficiency are paramount. It incorporates advanced condensing technology, allowing it to achieve high energy efficiency ratings while minimizing emissions. This model features a durable heat exchanger that enhances performance and longevity, making it an ideal choice for homeowners looking to reduce energy costs.

In contrast, the GS6 50 YBRT Series 200 is tailored for commercial settings, offering a robust heating solution with a larger capacity. This series emphasizes reliability and ease of maintenance, featuring a user-friendly control panel and diagnostic capabilities that streamline troubleshooting. It is equipped with high-quality insulation, which helps to retain heat and reduce operational costs.

The GS6 40 YBRT Series 201 is another commercial option that combines efficient heating with cutting-edge design. It utilizes an advanced modulation system to adjust output based on real-time demand, ensuring optimal energy consumption. This model's innovative design also includes rust-resistant materials, making it suitable for diverse environments.

For operators seeking versatility, the GS6 50 YBRS Series 201 provides a high-efficiency solution that can be used in various applications. With its quiet operation and compact footprint, it seamlessly blends into existing systems without disruption. Moreover, its integration with smart home technology allows for remote monitoring and control, enhancing convenience for users.

Lastly, the GS6 30 YOCT Series 200 stands out due to its compact design and remarkable efficiency in smaller spaces. This series is particularly suited for tight installations, while its innovative combustion system ensures reduced emissions and improved performance. Users can take advantage of its low noise levels, making it ideal for residential settings where comfort is crucial.

Overall, the State Industries GS6 series, with its range of models and features, is a testament to innovative engineering. Each unit is designed to offer optimal performance, efficiency, and reliability, catering to both residential and commercial heating needs. With advanced technologies and user-friendly features, these models provide an excellent solution for modern heating requirements.