Models: GS6 50 YOCT Series 200 GS6 30 YBRS Series 200 186489-002 GS6 50 YOCT Series 201 GS6 40 YBRS Series 200 GS6 40 YBRS Series 201 GS6 50 YBRS Series 200 GS6 30 YOCT Series 201 GS6 30 YBRT Series 200 GS6 30 YBRT Series 201 GS6 50 YBRT Series 201 GS6 30 YBRS Series 201 GS6 40 YOCT Series 200 GS6 40 YBRT Series 200 GS6 30 YOCT Series 200 GS6 50 YBRS Series 201 GS6 40 YBRT Series 201 GS6 50 YBRT Series 200 GS6 40 YOCT Series 201

1 36
Download 36 pages 6.3 Kb
Page 8
Image 8

IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of water, the tank will eventually leak after an extended period of time. Also any external plumbing leak, including those from improper installation, may cause early failure of the tank due to corrosion if not repaired. If the homeowner is uncomfortable with making the repair a qualified technician should be contacted. A suitable metal drain pan should be installed under the water heater as shown below, to help protect the property from damage which may occur from condensate formation or leaks in the piping connections

or tank. The pan must limit the water level to a maximum depth of 1-3/4” and be two inches wider than the heater and piped to an adequate drain. NOTE: The pan must not restrict combustion air flow. Locate the water heater near a suitable indoor drain. Outside drains are subject to freezing temperatures which can obstruct the drain line. The piping should be at least 3/4” ID and pitched for proper drainage.

METAL

DRAIN

PAN

PIPED TO AN

ADEQUATE DRAIN

AT LEAST 2” GREATER THAN THE

DIAMETER OF THE WATER HEATER.

EXHAUST FAN

REVERSE FLOW

OF GASES

FIGURE 1.

Clearances and Accessibility

NOTE: Minimum clearances from combustible materials are stated on the rating plate adjacent to the gas control valve/thermostat of the water heater.

The water heater is certified for installation on a combustible floor.

IMPORTANT: If installing over carpeting, the carpeting must be protected by a metal or wood panel beneath the water heater. The protective panel must extend beyond the full width and depth of the water heater by at least three inches (76.2mm) in any direction; or if in an alcove or closet installation, the entire floor must be covered by the panel.

Figure 2 may be used as a reference guide to locate the specific clearance locations. A minimum of 24 inch- es of front clearance should be provided for inspection and service.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VENT

BACK

TOP

 

 

 

 

 

 

 

 

 

 

 

 

 

SIDES

TO

 

 

 

 

 

 

CEILING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT

24” MINIMUM SIDES

FOR SERVICE

TOP

VIEW

Water heater life depends upon water quality, water usage, water temperature and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a drain pan piped to a drain. However, unanticipated damage can be reduced

or prevented by a leak detector or water shut-off device used in conjunction with a piped drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:

FIGURE 2.

State of California

NOTE: The water heater must be braced, anchored, or strapped to avoid moving during an earthquake. Contact local utilities for code requirements in your area, visit http:// www.dsa.dgs.ca.gov, or call 1-916-445-8100 and request instructions.

Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when water is detected.

Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan.

Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.

8

Page 8
Image 8
State Industries GS6 40 YBRS Series 201, 186489-002 Clearances and Accessibility, State of California

GS6 50 YOCT Series 200, GS6 30 YBRS Series 200, 186489-002, GS6 50 YOCT Series 201, GS6 40 YBRS Series 200 specifications

State Industries has a long-standing reputation for manufacturing high-quality heating equipment, and their GS6 series continues this tradition with advanced technology and robust features. The GS6 40 YOCT Series 201, GS6 50 YBRT Series 200, GS6 40 YBRT Series 201, GS6 50 YBRS Series 201, and GS6 30 YOCT Series 200 are notable additions to their product lineup, each designed to meet varying heating demands and efficiency standards.

The GS6 40 YOCT Series 201 is engineered for residential applications where space and efficiency are paramount. It incorporates advanced condensing technology, allowing it to achieve high energy efficiency ratings while minimizing emissions. This model features a durable heat exchanger that enhances performance and longevity, making it an ideal choice for homeowners looking to reduce energy costs.

In contrast, the GS6 50 YBRT Series 200 is tailored for commercial settings, offering a robust heating solution with a larger capacity. This series emphasizes reliability and ease of maintenance, featuring a user-friendly control panel and diagnostic capabilities that streamline troubleshooting. It is equipped with high-quality insulation, which helps to retain heat and reduce operational costs.

The GS6 40 YBRT Series 201 is another commercial option that combines efficient heating with cutting-edge design. It utilizes an advanced modulation system to adjust output based on real-time demand, ensuring optimal energy consumption. This model's innovative design also includes rust-resistant materials, making it suitable for diverse environments.

For operators seeking versatility, the GS6 50 YBRS Series 201 provides a high-efficiency solution that can be used in various applications. With its quiet operation and compact footprint, it seamlessly blends into existing systems without disruption. Moreover, its integration with smart home technology allows for remote monitoring and control, enhancing convenience for users.

Lastly, the GS6 30 YOCT Series 200 stands out due to its compact design and remarkable efficiency in smaller spaces. This series is particularly suited for tight installations, while its innovative combustion system ensures reduced emissions and improved performance. Users can take advantage of its low noise levels, making it ideal for residential settings where comfort is crucial.

Overall, the State Industries GS6 series, with its range of models and features, is a testament to innovative engineering. Each unit is designed to offer optimal performance, efficiency, and reliability, catering to both residential and commercial heating needs. With advanced technologies and user-friendly features, these models provide an excellent solution for modern heating requirements.