Sterilite Point-of-Use Drinking Water System owner manual Replacing The Uv Lamp, seal is in place

Models: Point-of-Use Drinking Water System

1 12
Download 12 pages 58.57 Kb
Page 9
Image 9
seal is in place
Figure 18 Installing the filter into the cap

Figure 17

Wet glass sleeve

cap. Push it firmly into the

cap until it is completely seated (Figure 18). The filter should stay firmly in the to cap.

12.Ensure that the lower filter O-ring

seal is in place

Figure 19

Figure 20

(Figure 19).

Checking lower O-ring seal

Installing the filter in the unit

13.The lower seal

 

 

slides over the

 

 

glass sleeve in the unit. Ensure that the glass sleeve is wet, and guide the filter over the sleeve (Figure 20).

Be sure to guide the outlet tube into the bottom fitting.

14.Tighten the cap and reconnect all fittings. Reconnect power.

15.Run water through the unit for 5 minutes to flush the filter before use.

(Figure 19). IMPORTANT! Use only filters supplied by your Sterilight dealer. Approved filters are specifically matched to your unit. Using the wrong filter will negatively effect unit operation, will void the unit warranty, and can adversely affect the safety of water leaving the unit.

REPLACING THE UV LAMP

The Sterilight unit uses a high-intensity ozone generating lamp which can be obtained from your Sterilight dealer. For proper unit operation, use only lamps supplied by your Sterilight dealer. The lamp should be replaced whenever it fails to light during operation.