6-2 Options for Pump Setup

Several of the items in this screen are not setup options but are instead intended for use during operation. These items (hour meter and transferring stations to a standby pump) are described in Chapter 4, which cover operation procedures.

Name

Description

Options

Default

Idle Time Options

 

 

 

Auto shutdown delay

Length of time the pump continues to run unloaded

0–999 sec.

45 sec.

 

without demand from any station. After this time has

 

 

 

elapsed, the pump shuts down to save power and to

 

 

 

prevent wear on the pump.

 

 

 

Adjust this setting to fit the needs of your facility

 

 

 

in trading off the savings against the costs

 

 

 

associated with waiting for a pump to start up

 

 

 

when there is a demand for material.

 

 

Alarm Options

 

 

 

Pump fault

The control has one input/pump that you can wire to

disabled,

disabled

 

generate alarms for situations of your choosing. For

enabled

 

 

example, you may have a sensor that turns on when

 

 

 

material reaches the top of a filter-chamber waste

 

 

 

bin. When this option is enabled, the controller issues

 

 

 

an alarm if the sensor wired to the input for Pump

 

 

 

Fault turns on.

 

 

 

Enable this option if and only if your facility has

 

 

 

installed a miscellaneous alarm on the input for

 

 

 

Pump Fault for this pump.

 

 

Blow Back Options

 

 

 

Blow back

When this option is enabled, the controller

disabled,

disabled

 

periodically sends compressed air backward through

vacuum pulse

 

 

the pump’s air filter to dislodge accumulated dust and

enabled

 

 

debris.

comp air

 

 

Enable this option if and only if the pump has the

enabled

 

 

equipment for compressed-air filter cleaning.

 

 

Every n loads

Number of conveying cycles to stations between filter

1–99

5

 

cleanings.

 

 

 

Adjust this setting based on experience. The more

 

 

 

dust and debris in your material line, the smaller this

 

 

 

number needs to be.

 

 

# pulses

Number of pulses of compressed air sent through the

1–99

5

 

pump’s filter during cleaning.

 

 

 

If filter-cleaning is not working as desired, the service

 

 

 

department may ask you to change this setting.

 

 

On time

Number of seconds that the air compressor remains

0.1–99.0 sec.

1.0 sec.

 

on for each pulse during filter cleaning.

 

 

 

If filter-cleaning is not working as desired, the service

 

 

 

department may ask you to change this setting.

 

 

Off time

Number of seconds between air pulses during filter

0.5–99.0 sec.

1.0 sec.

 

cleaning.

 

 

 

If blow-back is not working as desired, the service

 

 

 

department may ask you to change this setting.

 

 

3–Pump 33-Station Controllers

Chapter 6: Configurable Settings

44 of 51

Page 45
Image 45
Sterling Plumbing CV3-635, 882.00252.00 specifications Options for Pump Setup, Idle Time Options

882.00252.00, CV3-635 specifications

The Sterling Plumbing CV3-635,882.00252.00 is a revolutionary addition to home plumbing solutions, designed to enhance efficiency and convenience. This model stands out in the market due to its innovative features, advanced technologies, and sturdy characteristics, making it a reliable choice for homeowners and professionals alike.

One of the main features of the CV3-635 is its high water efficiency. Engineered to reduce water consumption without sacrificing performance, this plumbing fixture is ideal for environmentally conscious users. It is designed to meet or exceed regulatory standards for water flow, ensuring optimal operation while helping to conserve precious resources.

The CV3-635 also incorporates state-of-the-art technology, including SmartFlow technology, which allows for precise water temperature control. This feature ensures that users can enjoy consistent and comfortable water temperatures, eliminating the risk of sudden temperature fluctuations. With a user-friendly interface, adjustments can be made easily, accommodating the needs of every member of the household.

Durability is a key characteristic of the Sterling Plumbing CV3-635,882.00252.00. Constructed with high-quality materials, it resists leaks and corrosion, ensuring a long lifespan. The polished chrome finish not only enhances its aesthetic appeal but also provides added protection against wear and tear, making it a stylish yet practical addition to any bathroom or kitchen.

Installation of the CV3-635 is straightforward, thanks to its user-friendly design. This model is compatible with standard plumbing configurations, allowing for quick setup and minimal disruption. The comprehensive installation guide that accompanies the product ensures that even less experienced users can install it with confidence.

Another notable feature is its noise-reduction technology, which minimizes operational sounds, creating a quieter environment in the home. This is particularly beneficial in multi-story houses where plumbing sounds can disturb lower levels.

The Sterling Plumbing CV3-635,882.00252.00 is not just a plumbing fixture; it is a commitment to sustainability, performance, and style. With its innovative features, advanced technologies, and robust construction, it stands as a premium choice in modern plumbing solutions, appealing to both eco-conscious consumers and design-savvy homeowners.