Problem description

 

Probable cause

 

Action to take

 

 

 

 

 

 

 

 

 

 

Screen continues past bottom

 

White limit switch is out of

 

Readjust the white DOWN limit

stop position.

 

adjustment.

 

switch. See pp. 13-14 of this

 

 

 

 

manual.

Batten retracts too far into case.

 

Yellow limit switch out of

 

Have a qualified service person

 

 

adjustment. Failure to correct

 

readjust the yellow UP limit

 

 

can damage motor and screen.

 

switch. See pp. 13-14 of this

 

 

Do not use the unit until this

 

manual.

 

 

problem is resolved.

 

 

During operation, there is a

 

Motor cable or connectors are

 

Remove screenroll assembly and

repeated thumping or clicking

 

out of position in the case and

 

reposition cable and connectors

sound.

 

interfering with the screenroll.

 

so that they remain within the

 

 

 

 

electrical box when the screenroll

 

 

 

 

assembly is fitted back into the

 

 

 

 

case. See p. 11.

Motor shuts off. Motor has been

 

Motor is designed for short

 

Allow the motor to cool down.

in use for more than 2 minutes.

 

operations (lowering and

 

Complete cooling can take an

 

 

retracting), not continuous duty.

 

hour or more. Heat gain is

 

 

Longer operation, such as during

 

cumulative and takes time to

 

 

setup and positioning, causes

 

dissipate. If motor use is initiated

 

 

the motor to overheat and shut

 

before it has cooled completely,

 

 

off.

 

the motor will shut down again

 

 

 

 

when it reaches maximum

 

 

 

 

temperature.

Any controller (e.g., STI, LVC,

 

 

 

 

etc.) fails to operate motor.

 

 

 

 

Dirt, finger prints, marks, etc. on

 

Improper handling of screen.

 

Brush off or use a mild detergent

screen surface.

 

 

 

solution with clean rag or cotton

 

 

 

 

swab.

Indentations appear on screen

 

Debris or particles adhering to

 

Check back of screen; gently

surface.

 

screen due to static cling.

 

brush debris away by hand.