E.Connect the power cord. The plug is designed for 208/ 230 volt/20 amp duty. The unit must be connected to a properly grounded receptacle. The electrical cord furnished as part of the freezer has a three prong grounding type plug. The use of an extension cord is not recommended. If one must be used, use one with a size 12 gauge or heavier with a ground wire. Do not use an adaptor to get around grounding requirements.

CAUTION

DO NOT ALTER OR DEFORM PLUG IN ANY WAY!

F.Install the drip tray, cover and other miscellaneous parts on the freezer.

2.4 INSTALLING PERMANENT WIRING

If permanent wiring is required by local codes, the following procedure must be performed.

WARNING DISCONNECT FREEZER FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE SERVICING.

A.Remove the right side panel and electrical box cover to gain access to the power cord connection.

B.Disconnect the black and white wires from the termi- nal block (L1 and L2). Disconnect the green ground wire from the grounding screw.

C.Remove the strain relief connector from the bottom of the freezer base.Remove the power cord.

D.Install permanent wiring according to local code.

E.Connect black wire to L1 on the terminal block. Connect the white wire to L2 on the terminal block. Connect the green or yellow and green striped ground wire to the grounding screw.

F.Replace all panels.

4