SECTION 3

INITIAL SETUP AND OPERATION

3.1OPERATOR'SSAFETYPRECAUTIONS

SAFE OPERATION IS NO ACCIDENT; Observe these rules:

A.Know the freezer. Read and understand the Operating Instructions.

B.Notice all warning labels on the freezer.

C.Wear proper clothing. Avoid loose fitting garments, and remove watches, rings or jewelry which could cause a serious accident.

D.Maintain a clean work area. Avoid accidents by cleaning up the area and keeping it clean.

E.Stay alert at all times. Know which switch, push button or control you are about to use and what effect it is going to have.

F.Disconnect electrical cord for maintenance. Never attempt to repair or perform maintenance on the freezer until the main electrical power has been disconnected.

G.Do not operate under unsafe operating condi- tions. Never operate the freezer if unusual or exces- sive noise or vibration occurs.

3.2OPERATING CONTROLS AND INDICATORS Before operating the freezer, it is required that the operator know the function of each operating control. Refer to Figure 4 for the location of the operating controls on the freezer.

A.Pump OFF/ON Switch (Model SO318 only)

The pump OFF/ON Switch is a two position switch. In the OFF position the pump will not run. In the ON position the pump will run until the proper liquid level is reached, then stop. If the hopper does not fill completely, place the switch in the OFF position, then back to ON to continue filling.

WARNING

THE CLEAN/OFF/SERVE SWITCH MUST BE PLACED IN THE OFF POSITION WHEN DISASSEMBLING FOR CLEANING OR SERVICING. THE FREEZER MUST BE DISCONNECTED FROM ELECTRICAL SUPPLY BEFORE REMOVING ANY ACCESS PANEL.

B.CLEAN/OFF/SERVE Switch

The CLEAN/OFF/SERVE switch is a three position toggle and refrigeration switch used to control the operation of the agitator. When the switch is placed in the CLEAN position, the agitator will rotate.

When the switch is placed in the OFFposition, nothing will operate. When the switch in placed in the SERVE position, the agitator and refrigeration system will run until proper consistency is reached then stop.

C. Mix Low Light

The Mix Low light will illuminate when you are low on mix.

CAUTION

DO NOT OPERATE FREEZER WHEN THE LOW MIX LIGHT IS ILLUMINATED OR DAMAGE TO THE FREEZER COULD RESULT.

Pump Off/On

Switch

Ë

Ç

Clean Off/Serve

ÇSwitch

Mix Low

Light

Figure 4. Controls

3.3 DISASSEMBLY OF FREEZER PARTS

CAUTION

PLACE THE CLEAN/OFF/ON SWITCH IN THE OFF POSITION BEFORE DISASSEMBLING FOR CLEANING OR SERVICING.

Inspection for worn or broken parts should be made at every disassembly of the freezer for cleaning or other purposes. All worn or broken parts should be replaced to ensure safety to both the operator and the customer and to maintain good freezer performance and a quality product. Frequency of cleaning must comply with the local health regulations.

To disassemble the freezer, refer to the following steps:

A.Disconnect hose from hopper cover (Model SO318 only).

B.Remove hopper cover.

C.Remove retaining clip and adaptor (Model SO318 only).

D.Remove the front door by turning off the knobs, and then pull the front door off the studs.

5