2.4 INSTALLING PERMANENT WIRING
If permanent wiring is required by local codes, the following procedure must be performed.
WARNINGDISCONNECT FREEZER FROM THE SOURCEOF ELECTRICAL SUPPLY BEFORE SERVICING.A.Remove the right side and left panels and electrical box covers to gain access to the power cord.
B.Remove the strain relief connector from the bottom of the freezer base cut and remove the power cord.
C.Install permanent wiring according to local code.
D. Connect black wire to black wire. Connect the white | Figure 4. Electrical Box |
wire to white wire. Connect the green or yellow and |
|
green striped ground wire to the grounding screw. |
|
E. Replace all covers and panels. |
|
4