English
Operating instructions
11
- Open the lid, unscrew the fixing knob [7], pull out the beater [6] from the cylinder, then close the lid.
Note: The device will not operate when the lid is open.
- Press the BEATING Pushbutton [K2] and check that beater’s shaft turns CLOCKWISE (as shown in the picture). In
this case, the device is correctly connected and ready to be used;
Note: do not unnecessarily start the refrigerating system.
- If the rotation is COUNTERCLOCKWISE, the connection to the three-phase electrical supply is wrong, and
must be changed proceeding as follows:
- Turn off the device by pressing the ON/OFF Pushbutton [K1];
TURN THE SOCKET'S BREAKER ON “0” POSITION, THEN UNPLUG
THE MACHINE;
- Open the plug’s shell and invert TWO of the THREE conductors connected at the
phases (R- S, R- T or S- T);
- Close the plug’s shell, plug in the device and repeat the checking.
6MACHINE’S OPERATION
6.1 Warnings
WHEN USING THE DEVICE, AS WITH ALL ELECTRICAL APPARATUS, ESSENTIAL RULES MUST BE
COMPLIED WITH, PARTICULARLY:
- never touch it if your feet or hands are wet;
- never operate it while barefoot;
- never pull the supply cable to disconnect it from the main network;
- avoid liquids to penetrate in the device, for example during its cleaning;
- forbid children and unable people to operate it.
In case of failure and/or malfunctioning of the device - and every time you notice damages, mainly at the supply cable or at
the safety devices - turn off the power supply. Cont act qualified and certified personnel for assistance.
NEVER operate the machine in DRY conditions or with an amount of mixture other than the one recom-
mended.
NOT RESPECTING THESE RULES, IN ADDITION TO VOIDING ANY FORM OF WARRANTY, CAN SERI-
OUSLY COMPROMISE THE SAFETY, PERFORMANCES AND FUNCTIONING OF THE SAME DEVICE.