RMC-LCNG, RMC-LCLP, RMC-LING, RMC-LILP Specifications

Models

 

Input Rating

Regulator

Inlet Gas Supply

 

 

 

(Btu/Hr) Variable

Pressure

Pressure

Size

 

(Manual &

Gas Type

Weight

 

 

Setting

 

 

of Heater

Thermostat)

 

Min.

Max

Min.

Max

 

 

 

 

 

 

 

 

RMC-LC30NG

 

15,000

30,000

 

 

 

27”x 24”x8 ”

30 lbs.

 

 

 

 

 

 

 

1/2

 

RMC-LC20NG

Natural

10,000

20,000

4.0” w.c.

5.0” w.c.

11” w.c.

193/8”x227/8 ”x81/2

22 lbs.

 

 

 

 

 

 

 

 

 

RMC-LC10NG

 

5,000

10,000

 

 

 

151/2”x207/8 ”x77/8

17 lbs.

 

 

 

 

 

 

 

 

 

RMC-LC30LP

 

15,000

30,000

 

 

 

27”x24”x81/2

30 lbs.

 

 

 

 

 

 

 

 

 

RMC-LC20LP

LP

10,000

20,000

10” w.c.

11.0” w.c.

14.0” w.c.

193/8”x227/8 ”x81/2

22 lbs.

 

 

 

 

 

 

 

 

 

RMC-LC10LP

 

5,000

10,000

 

 

 

151/2”x207/8 ”x77/8

17 lbs.

 

 

 

 

 

 

 

 

 

RMC-LI30NG

 

6,400

30,000

 

 

 

27”x24”x81/2

30 lbs.

 

 

 

 

 

 

 

 

 

RMC-LI18NG

Natural

6,400

18,000

 

 

 

193/8”x227/8 ”x81/2

22 lbs.

 

 

 

 

 

 

 

 

RMC-LI10NG

5,500

10,000

 

 

 

151/2”x207/8 ”x77/8

17 lbs.

 

 

 

 

 

 

 

 

 

 

 

 

 

RMC-LI06NG

 

-

6,000

 

 

 

151/2”x207/8 ”x77/8

17 lbs.

 

 

 

 

 

 

 

 

 

RMC-LI30LP

 

6,400

30,000

 

 

 

27”x24”x81/2

30 lbs.

 

 

 

 

 

 

 

 

 

RMC-LI18LP

LP

6,400

18,00

10” w.c.

11.0” w.c.

14.0” w.c.

193/8”x227/8 ”x81/2

22 lbs.

 

 

 

 

 

RMC-LI10LP

5,500

10,000

151/2”x207/8 ”x77/8

17 lbs.

 

 

 

 

 

 

 

 

 

 

 

 

 

RMC-LI06LP

 

-

6,000

 

 

 

151/2”x207/8 ”x77/8

17 lbs.

 

 

 

 

 

 

 

 

 

NOTE: For altitude above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.

DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET

LOCAL CODES

RMC-LC30 / RMC-LC20 / RMC-LC10

RMC-LI30 / RMC-LI18 / RMC-LI10 / RMC-LI06

Certified to ANSI Z21.11.2b-2004 Unvented Heaters

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223.2, also known as NFPA54.

Available from:

 

American National

National Fire Protection

Standards Institute, Inc.

Association, Inc.

1430 Broadway

Batterymarch Park

New York, NY 10018

Quincy, MA 02269

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensor Shut- off system (ODS). The ODS pilot is a required feature for vent- free heaters. The ODS pilot shuts off the heater if the normal air oxygen content is reduced below 18%.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no match- es, batteries or other electrical sources to light the heater.