A-4 9710 System Assurance Guide MR0012J
Table A-5. Power Characteristics
Description Value / Part Identification Pictur e
Power drops for 9710 and PDU 1,
each:
(47-63 Hz AC range. 3-wire cables
supplied. International cables are
supplied without cable connectors)
U.S./Canada: 120 VAC, single phase
International: 200-240 VAC, single
phase
9710 120 VAC domestic plug feature
code 70DD
NEMA 5-20P, supplied with 9710
PDU 120 VAC domestic plug NEMA 5-15P, supplied by client
9710 120 VAC domestic wall
receptacle
NEMA 5-20R, supplied by client
PDU 120 VAC domestic wall
receptacle
NEMA 5-15R, supplied by client
International plugs and receptacles
for 9710 and, if applicable, for PDU
May be supplied by client according to
local electrical codes. See power
specifications below. See Table 4-1 on
page 4-9.
Current input for library without
drives 1
1.250 A at 120 VAC
0.625 A at 240 VAC
2.000 A at 120 VAC
Current input for each 4890 drive 11.000 A at 240 VAC
0.60 A at 120 VAC
0.30 A at 240 VAC
Power usage for library without
drives 1
Watts 150 peak / 100 Continuous
KVA 0.15 Peak / 0.10 Continuous