Stovax P8050 manual Installation Instructions, safety precautions, installation of the stove

Models: 8050 P8050

1 20
Download 20 pages 20.74 Kb
Page 10
Image 10
INSTALLATION

INSTALLATION INSTRUCTIONS

INSTALLATION

IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS AT THE FRONT OF THE BOOKLET.

LPG MODELS: THE APPLIANCE IS FACTORY SET TO RUN ON BUTANE G30. IF IT IS INTENDED TO BE USED ON PROPANE G31 THE AERATION PLATE SUPPLIED MUST BE FITTED.

FOR DETAILS OF CHANGING AERATION PLATES REFER TO SECTION 29.

FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 30.

1.safety precautions

1.1This appliance must be installed in accordance with the rules in force, and used only in a sufficiently ventilated space. Place read these instructions before installation and use of this appliance.

1.2All the instructions must be left intact with the user.

1.3In your own interest, and those of safety, this appliance must be installed by a competent person in accordance with local and national codes of practice. Failure to install the appliance correctly could lead to prosecution.

1.4This appliance is intended for use on a governed gas installation and set to the required pressure.

1.5Keep all plastic bags away from young children.

1.6Do not place any object on or near to the stove. Allow adequate clearance above the stove, see Technical Specification.

1.7The stove is fitted with the Gazco Flue Sure System, which will act to cut off the gas supply to the appliance in the event of incorrect operation of the flue. If the system acts to shut off the gas supply, this indicates that there is insufficient flue pull. If this occurs a minimum of 10 minutes should be allowed before trying to relight. Continued operation of this safety device means that there may be a serious problem with the flue system; a qualified gas engineer should inspect this. DO NOT USE THE STOVE UNTIL AN ENGINEER

SAYS IT IS SAFE TO DO SO.

1.8The Flue Sure System must not be tampered with. Use only genuine Gazco replacement parts when servicing the system

-refer to servicing section on page 15.

2.installation of the stove

2.1• Remove the outer carton

• Take the stove off the pallet and remove the accessory carton.

2.2• Position the stove ensuring all appropriate clearances are observed.

2.3Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls.

• Connect the gas supply to the 8mm-compression elbow at the RH rear corner of the stove, Diagram 3.

3

AR0396

2.4• Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening.

If there is a definite flow into the chimney, proceed with the installation, if not warm the chimney for a few minutes.

IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE

2.5The flue system may now be connected to the stove:

Ensure that all joints are sealed with a suitable fire resistant sealant.

It is also recommended that a physical retention method be used at the flue spigot joint, self-tapping screws being favoured.

2.6• Connect a suitable pressure gauge to the test point located on the inlet fitting,

Turn the gas supply on

Light the appliance and check all gas joints for possible leaks

Turn the appliance to a maximum and check that the supply pressure is as stated on the databadge.

Turn the gas off and replace the test point screw

Turn the gas on and check the test point for leaks.

NOTE: The stove is also suitable for installation onto a fireplace opening. The following method illustrates how this can be achieved with the aid of the optional closure plate and spigot extension:

Ensure that the fireplace dimensions are shown in

Diagram 4.