SERVICING INSTRUCTIONS
REPLACING PARTS
8.PRIMARY AERATION PLATE
8.1• Turn the gas supply off at the isolation device.
8.2To open the doors:
•Slacken the domed nut on the upper door and loosen the bolt from behind the latch
8.3• Remove the two screws securing the pilot unit and undo the injector nut, Diagam 6,B
6
AR0895
•Remove the four fixing screws and withdraw the burner unit, Diagram 6,C
8.4The aeration plate is located on the rear of the venturi: •
•Remove the fixing screw and replace with the correct plate
When replacing the plate:
•Ensure the lower edge is hooked over the flange of the venturi., Diagram 7,
7
AR0766
8.5• Replace the burner, ceramic components and check for leaks
• Close the doors and lock the bolts and nuts
9. CHANGING BETWEEN GAS TYPES
In order to change between gas types, it will be necessary to change the following items:
Burner Unit
Pilot Unit Control Valve Injector Aeration Plate Databadge
The relevant parts can be ordered from the parts list, always quote the appliance type and serial number when ordering spare parts.
*NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.
10. SHORT SPAES LIST
APPLIANCE | 8050 |
|
| P8050 |
| NG |
|
| LPG |
COMPONENT |
|
|
|
|
BURNER UNIT | GZ3279 |
|
| GZ3278 |
PILOT UNIT | PI0047 |
|
| PI0048 |
INJECTOR | IN0001 |
|
| IN0003 |
AERATION PLATE | G20 |
|
| G30 N/A |
GZ3269(C) |
| |||
|
| |||
|
|
| ||
| G25 |
|
| G31 |
| GZ3270(D) |
| GZ2003(A) | |
GAS VALVE |
| GC0056* | ||
FLUE SENSOR |
| EL0001 |
| |
SENSOR LEAD |
| EL0064 |
| |
INTERRUPTOR |
| GC0026 | ||
MAG UNIT |
| GC0016 | ||
PIEZO/IGN. UNIT |
| GC0062 | ||
GAS FILTER |
| GC0065 | ||
BURNER COVER | CE0358 |
|
| CE0359 |
REAR PANEL |
| CE0357 |
| |
FUEL BED |
| CE0356 |
| |
COAL SET |
| CE0284 |
| |
DATA BADGE |
| PR0397 |
|