Stovax AR0367 manual Servicing Instructions, Replacing Parts, Magnetic Safety Valve, Main Injector

Models: AR0368 AR0369 AR0887 AR0367 AR0366 Steel Manhattan AR0365

1 26
Download 26 pages 21.75 Kb
Page 20
Image 20
7.MAGNETIC SAFETY VALVE

SERVICING INSTRUCTIONS

REPLACING PARTS

6.3Undo the single screw that secures the left-hand side of the control cover, see diagram 10.

10

AR0915

6.4To release the right-hand side of the control cover, insert the narrow blade screwdriver into the slot shown in diagram 11. Lever it gently and pull from the right-hand side at the same time. The cover will now come off. There is a small cylindrical metal spacer inside the cover. This must be kept and replaced on the fixing screw during re-assembly.

11

AR0916

6.5Disconnect the ignition lead from the gas valve.

6.6Undo the two bolts securing the gas valve to the appliance and remove the valve.

6.7Replace in reverse order.

6.8Check all joints for gas leaks. Check operation of the thermocouple and ignition lead.

7.MAGNETIC SAFETY VALVE

7.1Turn the gas supply off at the isolation device. Undo the thermocouple connection from the back of the gas valve. Pull the sensor leads clear and remove the interrupter block.

7.2Undo the magnetic valve-retaining nut from the back of the control valve. Gently tap out the magnetic valve and replace with a new unit. Replace the retaining nut and tighten. See diagram 12.

12

7.3Reassemble the interrupter block and leads. Secure the thermocouple connection in the rear of the gas control. (Do not overtighten). Turn the gas supply on and check the entire pipework and valve joints for any leaks.

8.MAIN INJECTOR

8.1Turn the gas supply off at the isolation device. Locate the main injector on the LH side of the airbox, undo the compression nut and pull the pipe clear of the injector body, see diagram 13,A.

8.2Rotate the injector until it is fully removed, and install the

13

A

AR0498

correct replacement injector. Reassemble and turn the gas supply on, check for leaks.

.

20

Page 20
Image 20
Stovax AR0367, Steel Manhattan AR0365, AR0366 Servicing Instructions, Replacing Parts, Magnetic Safety Valve, Main Injector