![7.MAGNETIC SAFETY VALVE](/images/new-backgrounds/38516/3851639x1.webp)
SERVICING INSTRUCTIONS
REPLACING PARTS
6.3Undo the single screw that secures the
10
AR0915
6.4To release the
11
AR0916
6.5Disconnect the ignition lead from the gas valve.
6.6Undo the two bolts securing the gas valve to the appliance and remove the valve.
6.7Replace in reverse order.
6.8Check all joints for gas leaks. Check operation of the thermocouple and ignition lead.
7.MAGNETIC SAFETY VALVE
7.1Turn the gas supply off at the isolation device. Undo the thermocouple connection from the back of the gas valve. Pull the sensor leads clear and remove the interrupter block.
7.2Undo the magnetic
12
7.3Reassemble the interrupter block and leads. Secure the thermocouple connection in the rear of the gas control. (Do not overtighten). Turn the gas supply on and check the entire pipework and valve joints for any leaks.
8.MAIN INJECTOR
8.1Turn the gas supply off at the isolation device. Locate the main injector on the LH side of the airbox, undo the compression nut and pull the pipe clear of the injector body, see diagram 13,A.
8.2Rotate the injector until it is fully removed, and install the
13
A
AR0498
correct replacement injector. Reassemble and turn the gas supply on, check for leaks.
.
20