| SERVICING INSTRUCTIONS | |
| REPLACING PARTS | |
| 9. GAZCO FLUE SURE SYSTEM | 10.3 Remove the plate and replace with the correct size, ensure |
| that the hole(s) in the plate align correctly with the holes in | |
If the stove has been installed in a restrictive location, it | the underside of the airbox and replace the Nyloc nut. | |
| ||
may be necessary to remove the stove from its location. |
| |
9.1 Locate the sensor in the draught diverter opening, and | 11. CHANGING BETWEEN GAS TYPES | |
gently pull the two wires off the terminals. Undo the two | ||
taptite screws and remove the sensor and the two plastic |
| |
spacers. See diagram 14. |
| |
|
| 11.1 In order to change between gas types, it will be necessary |
14 |
| |
| to change the following items. | |
|
| • Pilot Unit |
|
| • Control Valve |
|
| • Main Injector |
|
| • Aeration Plate (if required) |
|
| • Databadge |
|
| The relevant parts can be ordered as a conventional kit |
|
| from Gazco. Always quote the appliance type and serial |
|
| number when ordering spare parts. |
|
| ** NOTE: THE CONTROL VALVE IS FACTORY PRESET |
|
| FOR CORRECT GAS TYPE AND MODEL. A NEW UNIT |
|
| WILL NEED TO BE ORDERED WHEN CHANGING |
|
| BETWEEN GAS TYPES. |
|
|
|
9.2Refit a new sensor ensuring the spacers are located between the sensor and the bracket. Replace the two leads.
9.3If it has been necessary to remove the stove, ensure that all disturbed gas joints are checked for gas soundness when reinstalled, and repeat the flue clearance test as detailed in the Commissioning Section.
10.PRIMARY AERATION PLATE
10.1Turn the gas supply off at the isolation device.
10.2Locate the aeration plate on the underside of the airbox and remove the Nyloc nut, see diagram 15.
15
AR0381
21