5.INSTALLATION - CONVECTOR FIRES

INSTALLATION INSTRUCTIONS

INSTALLATION

4.8 Fit the fret to the fire front using two screws. See diagram 4.

4

AR0311

5.INSTALLATION - CONVECTOR FIRES

5.1Make any necessary alterations to fireplace opening. Ensure that the lintel does not obstruct the flue outlet into the flue, and that there is a clear space for debris of at least 90mm. See diagram 5.

5

AR0300

5.2Gas pipe entry must be through one of the holes in the rear of the convector box. See diagram 6 & 7.

6

AR0200

Note: Gas pipes passing through masonry must be protected.

5.3If the isolation tap is to be fitted under the fire, the GAZCO GC0060 provides a neat and easy solution. See diagram 7A.

77A

5.4Remove the fire assembly (see diagram 9), and offer the convector box into the opening, checking that it fits squarely. Mark the fixing holes and the gas pipe entry positions. See diagram 8.

8

AR0313

5.5Fit the gas pipe into position, ready for passing into the convector box, ensuring enough remains to connect to the fire.

5.6Carefully fit the convector box, feeding the piping through into the box. Secure the box to the wall, through the flange or base ensuring that the box is square in the opening. Any undulations or gaps between the convector box and the wall should be filled with a non-combustible material. Do not use silicone as it makes future removal almost impossible.

5.7Refit the fire assembly and front air guide back into the convector box. See diagram 9.

9

AR0314

5.8HAVE YOU PURGED THE GAS SUPPLY PIPES.

This is essential to expel any foreign matter that might get blown into the valve assembly causing blockages.

12