Troubleshooting
*indicates qualified service technician recommended
Display flashes “hot” (OVERHEAT)
•This indicates that the heater body is over 112ºF. The system should be shut down in this state and will
Display flashes “HL” (HIGH LIMIT)
•This indicates that either the heater or the spa has reached 118ºF or higher. The system will not
Display flashes “FLO” (FLOW)
•This indicates that there is a water flow problem or defective pressure switch.
•make sure filters are clean
•check that service valves are open
•check for obstruction of flow
•adjust pressure switch (see pressure switch detail under description and use of controls)
Display flashes “FLC”*
• This indicates that the pressure switch is stuck in the closed position and should be replaced.
Erratic operation at topside panel* •Check for proper connection at J8
•Shut off system and restart
•Check for debris inside topside panel control housing
•Check cable connection at the topside control remove, clean reconnect.
•Try new topside control
•Replace main board
Pump(s), blower or light does not shut off*
•Try new topside control
•Replace main board
Circulation pump does not work*
• Check the fuse and power connections.
Light does not work
•Press Light to turn the light on/off. The Antigua Spa is equipped with an LED
Freeze Protect Over-ride FPO
This function is intended to be used on
By pressing the Jets 1 and Light key simultaneously for 10 seconds, the freeze protect feature will be suspend- ed for 6 hours. ( the FPO will be activated) This is to allow the installer of the spa to check for normal operation if the spa is filled with water that is less than the set freeze protect level 52ºF. FPO will appear every 10 sec- onds at the topside control. To manually go back to freeze protect mode, power down the system and