Strong Pools and Spas The Antigua Display flashes “hot” OVERHEAT, Display flashes “HL” HIGH LIMIT

Models: The Antigua

1 16
Download 16 pages 8.01 Kb
Page 10
Image 10
Display flashes “hot” (OVERHEAT)

Troubleshooting

*indicates qualified service technician recommended

Display flashes “hot” (OVERHEAT)

This indicates that the heater body is over 112ºF. The system should be shut down in this state and will re-start automatically when the water cools below 112ºF.

Display flashes “HL” (HIGH LIMIT)

This indicates that either the heater or the spa has reached 118ºF or higher. The system will not re-start automatically. To re-start the system, the water temperature must be below 112ºF and the heater key at the topside control must be pressed.

Display flashes “FLO” (FLOW)

This indicates that there is a water flow problem or defective pressure switch.

make sure filters are clean

check that service valves are open

check for obstruction of flow

adjust pressure switch (see pressure switch detail under description and use of controls)

Display flashes “FLC”*

• This indicates that the pressure switch is stuck in the closed position and should be replaced.

Erratic operation at topside panel* •Check for proper connection at J8

Shut off system and restart

Check for debris inside topside panel control housing

Check cable connection at the topside control remove, clean reconnect.

Try new topside control

Replace main board

Pump(s), blower or light does not shut off*

Try new topside control

Replace main board

Circulation pump does not work*

• Check the fuse and power connections.

Light does not work

Press Light to turn the light on/off. The Antigua Spa is equipped with an LED Multi-Color Light. The colors will cycle as you press the light button on and off.

Freeze Protect Over-ride FPO

This function is intended to be used on start-up after a fresh fill if water temp is below 52ºF. The 6 hour dura- tion of the FPO cycle is counted from the time the unit is powered-up and not from the time of its activation.

By pressing the Jets 1 and Light key simultaneously for 10 seconds, the freeze protect feature will be suspend- ed for 6 hours. ( the FPO will be activated) This is to allow the installer of the spa to check for normal operation if the spa is filled with water that is less than the set freeze protect level 52ºF. FPO will appear every 10 sec- onds at the topside control. To manually go back to freeze protect mode, power down the system and re-boot. It is recommended that the system be left on low speed and heating in FPO mode.

8

Page 10
Image 10
Strong Pools and Spas The Antigua Display flashes “hot” OVERHEAT, Display flashes “HL” HIGH LIMIT, Display flashes “FLC”