8 Technical Data

Technical data

Model

C 2600-24

C 4000-48

Inverter

Nominal battery voltage

12V

 

24V

 

 

48V

Input voltage range

9.5 - 16V

 

19 - 32V

 

 

38 - 64V

Continuous power @ 25°C

1300VA

 

2300VA

 

 

3500VA

Power 30 min. @ 25°C

1600VA

 

2600VA

 

 

4000VA

Maximum power load 5 sec.

 

 

3 x Pnom

 

 

 

Maximum load

 

 

up to short circuit

Maximum asymmetric load

 

 

up to Pcont.

 

 

 

Stand-by adjustment

 

 

1 to 25W

 

 

 

Cos ϕ

 

0.1 - 1

 

 

 

Maximum efficiency

94%

 

 

95%

Consumption OFF/Stand-by/ON

0.5/0.6/6W

 

0.8/0.9/9W

 

 

1.2/1.4/12W

Output voltage

 

 

230Vac (- 10% / 0)

 

 

Output frequency crystal controlled

 

 

50Hz +/- 0.05%

Total harmonic distortion

 

< 2%

 

 

 

Dynamic behaviour on load change 0 to 100%

 

 

0.5 ms

 

 

 

Overload and short circuit protection

Automatic disconnection with 3 time restart attempt

Overheat protection

Acoustic warning before shut-off - with automatic restart

Battery charger (4 STEP) I-U-Uo-Equalize (every 25 cycles)

 

 

 

 

 

Charging current adjustable

0 - 55A

 

0 - 55A

 

 

0 - 50A

Input current balance adjustment (Power Sharing)

 

 

1 - 16A

 

 

 

Maximum input voltage

 

 

265Vac

 

 

 

Minimum input voltage

Adjustable threshold from 150 to 230Vac

Input frequency

 

 

45 - 65Hz

 

 

 

Power Factor Correction (PFC)

 

 

EN 61000-3-2

Optional solar charger (4 stages) I-U-Uo-Equalize (every 25 cycles)

 

 

 

 

 

Maximum PV open circuit voltage (V)

25V

 

45V

 

 

90V

Maximum charge current (A)

30A

 

30A

 

 

20A

Working principle: I-U-Uo-Equalize (every 25 cycles)

 

 

Shunt

 

 

 

Battery control (thresholds and times adjustable by the user)

 

 

 

 

 

Absorption time

 

 

0-4 h

 

 

 

End charge cycle voltage

14.4V

 

28.8V

 

 

57.6V

Floating voltage

13.6V

 

27.2V

 

 

54.4V

Equalization voltage

15.6V

 

31.2V

 

 

62.4V

Deep-discharge protection

10.8V

 

21.6V

 

 

43.2V

Temperature compensation (optional CT-35)

 

 

-3mV / o C / cell

 

 

General data

 

 

 

 

 

 

Multifunction contact - potential free (3 points)

 

 

16A - 250Vac

Max. current on transfer relay

16A/3.7kVA

 

16A/3.7kVA

 

 

16A/3.7kVA

Transfer time

 

 

< 20 ms

 

 

 

Weight

16 kg

 

17.1 kg

 

 

29.4 kg

Dimension h x l x L [mm]

124x215x480

 

 

124x215x670

Protection index IP20

IP23 with top cover CxxxxIP23

Certification ECE-R 10 (E24)

yes

 

yes

 

 

n.a.

EC conformity

EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022,

EN 61000-3-2, Dir. 89/336/EEC, LVD 73/23/EEC

 

Operating temperature range

 

 

-20 to 55 oC

 

 

 

Ventilation

 

 

from 45 oC

 

 

 

Acoustic level without / with ventilation

 

 

< 10 dB / < 35 dB

Warranty

 

 

2 years

 

 

 

Options

 

 

 

 

 

 

Solar charge controller

C-xxxx-S

 

 

 

 

 

Remote control (112 x 138 x 25mm / 20 m. cable)

RCC-01

 

 

 

 

 

Remote power sharing (20 m. cable)

RPS-01

 

 

 

 

 

IP-23 top cover

C-xxxx-IP23

 

 

 

 

 

AC cable cover

CFC-01

 

 

 

 

 

Battery temperature sensor (58 x 51.5 x 22mm / 3 m.

CT-35

 

 

 

 

 

cable)

 

 

 

 

 

 

Data may change without any notice

 

 

 

 

 

 