Planning Information

Integrated Model 700BR

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.

IMPORTANT NOTE: The depth of Model 700BR is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the instal- lation illustration on page 4.

The anti-tip bracket must be installed to prevent the unit from tipping forward.

Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets.

The weight of each drawer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of 5/8" (16) thick.

For the bottom drawer, the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser.

We recommend using D-style handles, which should be located on the top, center area of the drawer panel.

Two Integrated units may be installed next to one another. Refer to page 10 for additional information.

A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary.

All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating

3-prong grounding type wall receptacle. The electrical outlet must be placed so the ground- ing prong is to the right of the thinner blades. The outlet must be flush with the back wall. Locate electrical within the shaded area shown in the installation illustration on page 4.

Do not use an extension cord or two prong adapter. Electrical ground is required on this appliance. Do not under any circumstances remove the power supply cord ground prong.

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

The Integrated Refrigeration Installation Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Page 5
Image 5
Sub-Zero 700BR dimensions Installation N O T E S