Planning Information
Integrated Model 700BR
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
IMPORTANT NOTE: The depth of Model 700BR is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the instal- lation illustration on page 4.
The
Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets.
The weight of each drawer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of 5/8" (16) thick.
For the bottom drawer, the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser.
We recommend using
Two Integrated units may be installed next to one another. Refer to page 10 for additional information.
A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary.
All Integrated models are equipped with a power supply cord with a
Do not use an extension cord or two prong adapter. Electrical ground is required on this appliance. Do not under any circumstances remove the power supply cord ground prong.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
The Integrated Refrigeration Installation Instructions packed with the appliance will give you
Dimensions in parentheses are in
millimeters unless otherwise specified. | 5 |