ELECTRICAL REQUIREMENTS
Electrical Requirements
GAS RANGE |
|
Electrical Supply | 110/120 V AC, 50/60 Hz |
Service | 15 amp dedicated circuit |
Receptacle | |
Power Cord | 6' (1.8 m) |
wolfappliance.com/specs
GAS SUPPLY REQUIREMENTS
Agas supply line of 3/4" (19) rigid pipe must be provided to the range. If local codes permit, a certified, 3' (.9 m) long,
1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the units 1/2" NPT female inlet to the gas supply line.
Wolf natural and LP gas ranges will function up to 10,250' (3124 m) in altitude without adjustment. If the installation is above 10,250' (3124 m), contact your authorized Wolf dealer for a high altitude conversion kit.
Gas Supply Pressure
NATURAL GAS |
|
Gas Supply Pressure | 5" (12.5 mb) WC |
Min Line Pressure | 7" (17.5 mb) WC |
Max Pressure to Regulator | 14" (34.9 mb) WC, .5 psi (3.5 kPa) |
LP GAS |
|
Gas Supply Pressure | 10" (25 mb) WC |
Min Line Pressure | 11" (27.4 mb) WC |
Max Pressure to Regulator | 14" (34.9 mb) WC, .5 psi (3.5 kPa) |
|
|