2.42x7 Cabling

2.4.1SCSI Cabling

2.4.1.1Cable Lengths

The following tables show the lengths of each SCSI cable connected to the drive connections on the respective controller modules.

TABLE 2-7Controller Module A (2x7)

SCSI Port Number

Cable Length

Part Number

 

 

 

1

.8m

530-1884-xx

2

.8m

530-1884-xx

3

.8m

530-1884-xx

4

2m

530-1885-xx

5

2m

530-1885-xx

 

 

 

TABLE 2-8Controller Module B (2x7)

SCSI Port Number

Cable Length

Part Number

 

 

 

1

2m

530-1885-xx

2

.8m

530-1884-xx

3

.8m

530-1884-xx

4

2m

530-1885-xx

5

2m

530-1885-xx

 

 

 

The inboard IN/OUT connectors on each of the top four disk arrays are connected together using a 0.2m SCSI jumper cable, part number 530-1883-xx.

The inboard IN/OUT connectors on the bottom three disk arrays are terminated with differential SCSI terminators, part number 150-1890-xx.

Chapter 2 StorEdge A3500 Configurations 2-17

Page 33
Image 33
Sun Microsystems A3500 manual 2x7 Cabling, 7Controller Module a, 8Controller Module B