30 Sun Fire T1000 Server Service Manual • January 2006
TABLE2-6 shows typical combinations of ALOM variables and associated POST

mode.

To Change POST Parameters

1. Access the ALOM sc> prompt:

At the console, issue the #. key sequence:

2. At the ALOM sc> prompt, use the setsc command to set the POST parameter:

Example:

The setkeyswitch parameter is a command that sets the virtual keyswitch, so it

does not use the setsc command. Example:

TABLE2-6 ALOM Parameters and POST Modes
Parameter Normal Diagnostic
Mode
(default settings)
No POST
Execution
Diagnostic
Service Mode
Keyswitch
Diagnostic preset
values
diag_mode normal off service normal
setkeyswitch*
* Thesetkeyswitch parameter, when set to diag, overrides all the other ALOM POST variables.
normal normal normal diag
diag_level max n/a max max
diag_trigger power-on-reset
error-reset
none all-resets all-resets
diag_verbosity normal n/a max max
Descriptionof POST
execution
Thisis thedefault POST
configurationand
providesa reasonable
compromisebetween
testing thoroughness
and quick server
initialization.
POST does not
run, resultingin
quick system
initialization, but
this is not a
suggested
configuration.
POST runs the
full spectrum of
tests with the
maximumoutput
displayed.
POST runs the
full spectrum of
tests with the
maximumoutput
displayed.

#.

sc> setsc diag_mode service

sc> setkeyswitch diag