
70 Sun Fire T1000 Server Service Manual • January 2006
6. Replace the memory DIMMs.
“ToAdd orReplace DIMMs”on page66.
7. Replace the socketed system configuration SEEPROM.
The location of this SEEPROM is shown in Appendix A,“Field-Replaceable Units
(FRUs)” on page 75.
8. Perform the procedures described in “Common Procedures for Finishing Up” on
page72 .
9. Boot the system and run POST to verify that the system is fully operational. See
“Running POST” on page 27.
▼To Remove the Clock Battery on the
Motherboard1. Perform the procedures described in “Common Procedures for Parts
Replacement” on page 53.
2. Using a small flat head screwdriver, carefully pry the battery (FIGURE 3-12) from the
motherboard.
FIGURE3-12 Removing the Clock Battery from the Motherboard