34 Sun Fire T1000 Server Service Manual • January 2006
under test above
c:s> MSG = test-error-message
c:s> END_ERROR
where c= the core number,s= the strand number.
Warningand informational messages use the following syntax:
INFO or WARNING:message
The following is an example of a POST error message.
In this example, POST is reporting a memory error at DIMM location
MB/CMP0/CH0/R1/D0. (J0701).
b. Run the showfaults command to obtain additional fault information.
The fault is captured by ALOM, where the fault is logged, the Service required
LED is lit, and the faulty component is disabled.
.
.
.
0:0>Data Bitwalk
0:0>L2 Scrub Data
0:0>L2 Enable
0:0>Testing Memory Channel 0 Rank 0 Stack 0
0:0>Testing Memory Channel 3 Rank 0 Stack 0
0:0>Testing Memory Channel 0 Rank 1 Stack 0
.
.
.
0:0>ERROR: TEST = Data Bitwalk
0:0>H/W under test = MB/CMP0/CH0/R1/D0/S0 (J0701)
0:0>Repair Instructions: Replace items in order listed by ’H/W
under test’ above.
0:0>MSG = Pin 3 failed on MB/CMP0/CH0/R1/D0/S0 (J0701)
0:0>END_ERROR
0:0>Testing Memory Channel 3 Rank 1 Stack 0