Chapter 3 Removing and Replacing FRUs 67
6. Perform the following steps to clear the memory fault.
a. Gain access to the ALOM sc> prompt.
Refer to the Sun Fire T2000 Server Advanced Lights Out Management (ALOM)
Guide for instructions.
b. Run the showfaults -v commandto determine how to clear the fault:
If the fault is a Host-detected fault (displays aUUID), such as the following:
Run the showfaults -v command to obtain the UUID to clear the fault:
If the fault resulted in the DIMM being disabled, such as the following:
Run the enablecomponent command to enable the FRU:
7. Perform the following steps to verify that there are no faults:
a. Set the virtual keyswitch to diag mode so that POST will run in service mode.
b. Issue the poweron command.
sc> showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26 MB/CMP0/CH0/R0/D0 Host detected fault
MSGID:
SUN4U-8000-2S UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> clearfault 7ee0e46b-ea64-6565-e684-e996963f7b86
Clearing fault from all indicted FRUs...
Fault cleared.
sc> showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27 MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0
deemed faulty and disabled
sc> enablecomponent
sc> setkeyswitch diag
sc> poweron