Page 12
ELITE SERIES
5.1 North American 60 Hz Power Options
North American 2-Pump Models (60 Hz)
240v/40A* 240v/50A** 240v/60A***
Voltage: 240 VAC 240 VAC 240 VAC
# of Wires: 3 3 3
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 26A 36A 45A
Circuit Breaker: 40A*, 2-Pole 50A**, 2-Pole 60A***, 2-Pole
* In 40A conguration, the heater will not operate while either jets pump is
running in high speed. Note: pump 2 runs only in high speed.
** In 50A conguration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed. This
is the factory setting.
*** In 60A conguration, the heater will operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.
5.2 Export 50 Hz Power Options
Export 2-Pump Models (50 Hz)
230v/20A* 230v/30A** 230v/40A***
Voltage: 230 VAC 230 VAC 230 VAC
# of Wires: 3 3 3
Frequency: 50 Hz 50 Hz 50 Hz
Current Draw: 15A 23A 29A
Circuit Breaker: 20A* 30A** 40A***
* In 20A conguration, the heater will not operate while either jets pump is
running in high speed. This is the factory setting. Note: pump 2 runs
only in high speed.
** In 30A conguration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
*** In 40A conguration, the heater will operate while both jets pump are
running in high speed. Note: pump 2 runs only in high speed.