Bali 120 VAC Service Connection1. Remove the center cabinet panel directly under the hot tub’s control panel.
2. Locate and unroll the GFI protected power cord.
3. Replace cabinet panel making sure cord passes through notch.
Refer to additional instructions in box on page 8.
* Power cord is not available for Canada - the hot tub must be hard wired.
Table No. 1
Power Supply Options and RequirementsSweetwater hot tubs are designed to provide optimum performance and flex-
ibility of use when connected to the maximum electrical service as listed
below. Bali is shipped configured for 120V, 15A connection with a GFI pro-
tected cord provided.
If you prefer, your Sweetwater dealer can perform a minor circuit board mod-
ification to allow the hot tub to accept different electrical service. The opera-
tional considerations of these modifications are listed in the footnotes located
at the end of this section.
PALERMO and BAHIA DOMESTIC MODELS (60 Hz)
240V/30A*240V/50A
Voltage 240 volts 240 volts
Current Draw 24 amps 40 amps
Number of Wires Three Three
Circuit Breaker 30 amp dual pole 50 amp dual pole
In 50A configuration, the heater will not operate while both the pumps are
operating at high speed.
ARUBA and CYPRUS DOMESTIC MODELS (60 Hz)
240V/30A*240V/40A
Voltage 240 volts 240 volts
Current Draw 24 amps 32 amps
Number of Wires Three Three
Circuit Breaker 30 amp dual pole 40 amp dual pole