BALI DOMESTIC MODEL (60 Hz)**
120V/15A 240V/30A *240V/40A ***
Voltage 120 volts 240 volts 240 Volts
Current Draw 12 amps 22 amps 28 amps
No. of Wires Three (15 amp cord) Four Four
Circuit Breaker 15 amp 30 amp dual pole 40 amp dual pole
PALERMO and BAHIA EXPORT MODELS (50 Hz)
230V/25A*230V/30A
Voltage 230 to 240 volts 230 to 240 volts
Current Draw 18 amps 24 amps
No. of Wires Three Three
Circuit Breaker 25 amp dual pole 30 amp dual pole
In 50A configuration, the heater will not operate while the pumps are oper-
ating at high speed.
ARUBA, BALI and CYPRUS EXPORT MODELS (50 Hz)
230V/20A*230V/30A
Voltage 230 to 240 volts 230 to 240 volts
Current Draw 14 amps 20 amps
No. of Wires Three Three
Circuit Breaker 20 amp dual pole 25 amp dual pole
In 40A configuration, the heater will operate while the pump is operating
at high speed. This also applies to export Palermo and Bahia 30A and
export Aruba, Bali and Cyprus 25A.
*In this configuration, the heater will not operate at the same time as the
high speed of either pump. Note: Pump 2 in Palermo and Bahia models
runs only in high speed.
** Bali Domestic Models Only (60 Hz) - For 240V connection of the Bali
move the red wire from position #1 to position #3 on the terminal block
(see Illustration 4, page 10).
***Bali Domestic Models Only (60 Hz) - If the Bali is to be operated on
240 VAC, 40A service, remove the jumper at location JP1-1 on the circuit
board. 30A, 240 VAC operation increases the output capacity of the heater
four-fold compared to 120 VAC. However, the heater cannot operate when
the pump is on high speed. 40A, 240 VAC operation allows the heater to
operate at the same time as the high speed pump.
Page 13