IMPORTANT SAFETY INSTRUCTIONS:READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
When installing and using this electrical equipment, basic safety precautions
should always be followed, including:
1) WARNING: To r educe the risk of injury, do not permit children to use this
product unless they are closely supervised at all times.
2) WARNING: A grounding wire connector is provided on this unit to con-
nect a minimum No. 8AWG (8.4mm2) solid copper conductor between
this unit and any metal equipment, metal enclosures of electrical equip-
ment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.
3) DANGER: Risk of Accidental Drowning. Extreme caution must be exer-
cised to prevent unauthorized access by children. To avoid accidents,
ensure that children cannot use this hot tub unless they are supervised
at all times.
4) DANGER: Risk of Injury. The suction fittings in this hot tub are sized to
match the specific water flow created by the pump. Should the need
arise to replace the suction fittings or the pump, be sure that the flow
rates are compatible. Never operate the hot tub if the suction fittings are
broken or missing. Never replace a suction fitting with one rated less than
the flow rate marked on the original suction fitting.
5) DANGER: Risk of Electric Shock. Install at least 5 feet (1.5m), from all
metal surfaces. As an alternative, a hot tub may be installed within 5 feet
(1.5m) of metal surfaces if each metal surface is permanently connected
(bonded) by a minimum No. 8 AWG (8.4 mm2) solid copper conductor
attached to the wire connector on the grounding lug, inside the equip-
ment compartment on the equipment box.
6) DANGER: Risk of Electric Shock. Do not permit any electrical appliance,
such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a
hot tub.
7) ELECTRICAL SUPPLY: The electrical supply for this product must
include a suitably rated switch or circuit breaker to open all ungrounded
supply conductors to comply with section 422-20 of the National
Electrical Code, ANSI/NFPA 70. The disconnect must be readily accessi-
ble and visible to the hot tub occupant but installed at least 5 feet (1.5m),
from the hot tub water.