Page 28

Electrical Wiring Diagram
Bali Domestic (60 Hz)

NOTE: FOR240 VOLTS PERMANENTLY CONNECTED UNIT:

1. MOVE THE RED WIRE FROM POS. 1 TO POS. 3 ON THE TB1

TERMINAL BLOCK.

2. IF THE SPA IS TO BE OPERATED ON A 40A SERVICE. REMOVE THE

JUMPER PROVIDED AT LOCATION JP1-&2..

Note: For 240 VAC 4-Wire Permanent Connected Unit:
1. Remove and discard the GFCI Cord
2. Permanently connect to the power supply. The electrical wiring
MUST meet the requirements of NEC or local codes.
3. Move the RED wire from position 1 to position 3 on the TB1
terminal block (left).
4. If the hot tub is to be operated on 40A service, remove the
jumper provided at location JP1 #1&2 on circuit board.