IR
Symptom | Cause | Solution |
No control | 1. Programming: | Verify and correct program- |
of IR | missing or incorrect | ming. Test IR commands from |
sources. | IR commands. | SunTools. |
| 2. Wiring: Incorrect | Verify and correct wiring. |
| wiring between Zone |
|
| and |
|
| 3. Wiring: IR emitter | Verify port connection and |
| connected to wrong | correct. |
| source IR port of |
|
|
| |
| IR emitter defective. | Replace IR emitter. |
Intermit- | IR flooding. | Check to see if any ambi- |
tent source |
| ent light is shining on built in |
control. |
| IR receiver or in direct line |
|
| with plasma TV noise. If the |
|
| |
|
| disable the IR receiver in |
|
| SunTools setup software and |
|
| use a plasma friendly external |
|
| receiver as shown on page 14 |
|
| of this manual. If installed in |
|
| conjunction with an |
|
| |
|
| refer to its own troubleshooting |
|
| steps. |
22