X . S E T U P & A D J U S T M E N T

X . S E T U P & A D J U S T M E N T

N. CASTER MOUNTING

(not available on the 500)

1.Forward or Rearward Placement

a.Remove caster housing covers.

b.Remove the two eccentric bolts from each caster.

c.Move left-side caster to right side.

d.Move right-side caster to left side.

e.Remount casters to caster bracket.

Note: Sunrise recommends mounting casters for-

ward whenever possible.

O.BACKREST BREEZY 600

1.Height Adjustment

a.Remove backrest material.

b.There are three holes, 1” apart, in each backrest tube (1).The tube tele- scopes into the frame and is secured by a bolt on the side of the frame. Choose one of the three holes to set the back height.

c.Remove bolt (2) from each backrest tube.

d.Choose the proper height. Slide the upholstery back on.

Note: Do not attach the overlap portion.

1

5, 6

3

2

4

BREEZY 500 & 510

Note: Use a torque setting of 20-30 in./lbs. (2.3-3.4 N.m) to tighten bolts.

1.Height Adjustment

a.Remove bolt which attaches metal upholstery tab to frame tube.

b.The backrest tube telescopes into the frame and is secured by a bolt on the side of the frame.

c.Remove bolt.

d.There are three holes, 1” apart, you may choose from to set the back height.

e.After selecting the proper height reat- tach the metal upholstery tab to bolt.

f.Tighten nut and bolt assembly.

e.Attach tab (3) to bolt (2) and tighten nut (4).

f.Insert nylon tie (5) through grommets

(6). Secure tie and cut off excess nylon.